Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by Luís Carlos Coelho

2012

Interferometer based on a d-shape chaotic optical fiber for measurement of multiparameters

Authors
Silva, S; Coelho, L; Roy, P; Frazao, O;

Publication
Photonic Sensors

Abstract
An interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters was proposed. The sensing structure relied on a D-shape fiber section spliced in between two singlemode fibers and interrogated in transmission. The optical spectrum was composed by multiple interference loss peaks, which were sensitive to the refractive index, temperature and strain-maximum sensitivities of 95.2 nm/RIU, 10.5 pm/ and -3.51 pm/µe, respectively, could be achieved. © The Author(s) 2012.

2012

Multimode interference in outer cladding large-core, air-clad photonic crystal fiber

Authors
Coelho, L; Kobelke, J; Schuster, K; Frazao, O;

Publication
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
It is described a large-core air-clad photonic crystal fiber-based sensing structure using the outer cladding as a light guide, which is highly sensitive to refractive index. The sensing head is based on multimodal interference, and relies on a single mode/large-core air-clad photonic crystal fiber/single mode fiber configuration. Using this configuration and controlling the light to travel in a segment of the outer cladding multimode fiber, it was possible to implement a sensing head and the results were obtained independently from variations of temperature, strain and refractive index. (c) 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:10091011, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26726

2011

Fabry-Perot cavity based on a diaphragm-free hollow-core silica tube

Authors
Ferreira, MS; Coelho, L; Schuster, K; Kobelke, J; Santos, JL; Frazao, O;

Publication
OPTICS LETTERS

Abstract
A Fabry-Perot (FP) cavity of simple design and based on a pure silica diaphragm-free hollow tube is proposed. Its operation is based on a first reflection of light at the end of the single-mode fiber that illuminates the silica rod and in a second reflection that takes place at the end of the rod. The FP cavity is characterized for high temperature, pressure and refractive index sensing, showing useful characteristics for the measurement of these three parameters. The diaphragm-free configuration simplifies the measurement of the refractive index of fluids. (C) 2011 Optical Society of America

2012

A Review of Palladium-Based Fiber-Optic Sensors for Molecular Hydrogen Detection

Authors
Silva, SF; Coelho, L; Frazao, O; Santos, JL; Xavier Malcata, FX;

Publication
IEEE SENSORS JOURNAL

Abstract
Palladium-based fiber-optic sensors have been one of the most promising configurations for hydrogen sensing. In the latest decade, fiber-optic sensors have indeed earned a strong interest owing to their ability to monitor molecular hydrogen at specific spatial points-either as a sensing tip device or in large areas via multiple sensing regions distributed along the optical fiber. This review focuses on the various types of optical fiber hydrogen sensors, containing specifically palladium as active element. Three distinct working principles are described, viz. interferometric-, intensity-, and fiber grating-based sensors; their characteristics and sensing performances are critically overviewed.

2012

Simultaneous measurement of partial pressure of O-2 and CO2 with a hybrid interferometer

Authors
Coelho, L; Tafulo, PAR; Jorge, PAS; Santos, JL; Viegas, D; Schuster, K; Kobelke, J; Frazao, O;

Publication
OPTICS LETTERS

Abstract
In this Letter, a hybrid interferometer for simultaneous measurement of the partial pressures of O-2 and CO2 mixtures is reported. The sensing head consists in the combination of two interferometric structures, one a Fabry-Perrot cavity and the other a modal interferometer. The intrinsic Fabry-Perot was formed by splicing a single mode fiber with a graded index fiber length that was then subjected to chemical etching creating an air cavity. The second interferometer is based on a splice of a pure silica tube in series with the Fabry-Perot. It was observed for a particular gas that its refractive index changes with pressure variation in a specific way, a characteristic that permitted the simultaneous measurement of partial pressures of CO2 and O-2 with rms deviations of similar to +/- 48.7 kPa and similar to +/- 20.1 kPa, respectively. (C) 2012 Optical Society of America

2010

Long-Period Grating Fiber Sensor With In Situ Optical Source for Remote Sensing

Authors
Viegas, D; Carvalho, JP; Coelho, L; Santos, JL; Araujo, FM; Frazao, O;

Publication
IEEE PHOTONICS TECHNOLOGY LETTERS

Abstract
A concept of long-period-based optical fiber sensors, with broadband light illumination generated just after the sensing structure, is presented in this work. This new approach allows the interrogation in transmission of the sensing head while integrated in a reflective configuration, which means the long-period grating (LPG) sensor is seen in transmission by the optical source but in reflection by the measurement system. Also, it is shown that with this illumination layout the optical power balance is more favorable when compared with the standard configurations, allowing better sensor performances, particularly when the sensing head is located far away from the photodetection and processing unit. This is demonstrated for the case of the LPG structure applied to measure strain and using ratiometric interrogation based on the readout of the optical power reflected by two fiber Bragg gratings spectrally located in each side of the LPG resonance.

  • 27
  • 30