2009
Authors
Escada, J; Coelho, LCC; Dias, THVT; Lopes, JAM; dos Santos, JMF; Breskin, A;
Publication
JOURNAL OF INSTRUMENTATION
Abstract
Experimental measurements of the extraction efficiency f of the UV-induced photoelectrons emitted from a CsI photocathode into gas mixtures of Ne with CH4, CF4, CO2 and N-2 are presented; they are compared with model-simulation results. Backscattering of low-energy photoelectrons emitted into noble gas is significantly reduced by the admixture of molecular gases, with direct impact on the effective quantum efficiency. Data are provided on the dependence of f on the type and concentration of the molecular gas in the mixtures and on the electric field.
2008
Authors
Angle, J; Aprile, E; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Coelho, LCC; Dahl, CE; DeViveiros, L; Ferella, AD; Fernandes, LMP; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kastens, L; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, DN; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Plante, G; Santorelli, R; dos Santos, JMF; Shagin, P; Shutt, T; Sorensen, P; Schulte, S; Winant, C; Yamashita, M;
Publication
PHYSICAL REVIEW LETTERS
Abstract
XENON10 is an experiment to directly detect weakly interacting massive particles (WIMPs), which may comprise the bulk of the nonbaryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with (129)Xe and (131)Xe from 58.6 live days of operation at the Laboratori Nazionali del Gran Sasso. Based on the nonobservation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of similar to 10 GeV/c(2) -2 TeV/c(2) as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
2010
Authors
Sorensen, P; Angle, J; Aprile, E; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Coelho, LCC; Dahl, CE; DeViveiros, L; Ferella, AD; Fernandes, LMP; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kastens, L; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, DN; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Plante, G; Santorelli, R; Dos Santos, JMF; Schulte, S; Shagin, P; Shutt, T; Winant, C; Yamashita, M;
Publication
Proceedings of Science
Abstract
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~ 1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal. © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.
2008
Authors
Aprile, E; Giboni, KL; Kamat, S; Monzani, ME; Plante, G; Yamashita, M; Gaitskell, RJ; Fiorucci, S; Sorensen, P; DeViveiros, L; Bernstein, A; Madden, N; Winant, C; Shutt, T; Kwong, J; Bolozdynya, A; Dahl, E; Oberlack, U; Shagin, P; Gomez, R; McKinsey, D; Manzur, A; Hasty, R; Ni, K; Arneodo, F; Ferella, A; Baudis, L; Angle, J; Orboeck, J; Manalaysay, A; Lopes, JAM; Coelho, L; Fernandes, L; Santos, J;
Publication
Nuclear Physics B - Proceedings Supplements
Abstract
2008
Authors
Angle, J; Aprile, E; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Coelho, L; Dahl, E; DeViveiros, L; Ferella, A; Fernandes, L; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kamat, S; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, D; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Plante, G; Santos, J; Shagin, P; Shutt, T; Sorensen, P; Winant, C; Yamashita, M;
Publication
Nuclear Physics B - Proceedings Supplements
Abstract
2007
Authors
Montelro, CMB; Fernandas, LMP; Lopes, JAM; Coelho, LCC; Veloso, JFCA; Dos Santos, JMF; Glbonr, K; Aprlle, E;
Publication
Journal of Instrumentation
Abstract
The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as a reference for the determination of the number of charge carriers produced by the scintillation pulse and, thus, the number of VUV photons impinging the photodiode. A value of 140 photons/kV was obtained for the scintillation amplification parameter. The attained results are in good agreement with those predicted, for room temperature, by Monte Carlo simulation and Boltzmann calculations, as well as with those obtained for saturated xenon vapour, at cryogenic temperatures, and are about a factor of two higher than former results measured at room temperature. © 2007 IOP Publishing Ltd and SISSA.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.