2024
Authors
Robalinho, P; Rodrigues, A; Novais, S; Ribeiro, ABL; Silva, S; Frazao, O;
Publication
2024 IEEE PHOTONICS CONFERENCE, IPC 2024
Abstract
This work presents an implementation of a reference optical cavity based on parasitic cavities on a low coherence interferometric system. This method allows a maximization of the number of sensors to be implemented without occupying additional reading channels.
2026
Authors
Robalinho, P; Piaia, V; Lobo-Ribeiro, A; Silva, S; Frazao, O;
Publication
IEEE PHOTONICS TECHNOLOGY LETTERS
Abstract
The present letter proposes the implementation of Vernier-effect harmonics through the virtualization of different reference cavities. A Fabry-Perot interferometer (FPI), actuated by a piezoelectric transducer (PZT), was employed as the sensing element. Subsequently, the sensitivity of the dynamic range was investigated for both the individual interferometer and the implementation of the Virtual Vernier effect. A sensitivity of (8 +/- 0.05)x10(-3) nm/nm was achieved for the single sensor measurement. Considering the implementation of the Vernier effect, the following sensitivities were obtained: (65.6 +/- 0.08)x10(-3) nm/nm for the fundamental, (132 +/- 1)x10-3 nm/nm for the first harmonic, and (192 +/- 1)x10(-3) nm/nm for the second harmonic. Furthermore, a maximum dynamic range of 11.25 mu m and a maximum resolution of 5 pm were achieved. This study highlights the advantages of simultaneously measuring both a single sensor cavity and a harmonic of the Virtual Vernier effect, in order to achieve large dynamic ranges along with high resolution.
2025
Authors
Piaia, V; Robalinho, P; Rodrigues, A; Ribeiro, AL; Silva, S; Frazao, O;
Publication
IEEE PHOTONICS TECHNOLOGY LETTERS
Abstract
In this letter, we propose a method for utilizing the internal cavities of optical circulator devices-commonly referred to as parasitic cavities-as optical reference cavities. The method involves using an optical circulator operating at 1550 nm, illuminated by a light source at 1330 nm, thereby enhancing the amplitude of the interferometric signals generated by the internal optical cavities. The system was characterized by using both an Optical Spectrum Analyzer (OSA) and the Low-Coherence Interferometry (LCI) technique. Experimental results indicate that the Optical Path Difference (OPD) remains constant with varying aperture sizes, thereby confirming the feasibility of employing the optical circulator as a reference sensor. Finally, its performance as a reference sensor is demonstrated through its integration with an external cavity that functions as a displacement sensor.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.