Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CPES

2024

A Practical Methodology for Real-Time Adjustment of Kalman Filter Process Noise for Lithium Battery State-of-Charge Estimation

Authors
da Silva, CT; Dias, BMD; Araújo, RE; Pellini, EL; Laganá, AAM;

Publication
BATTERIES-BASEL

Abstract
The methodology presented in this work allows for the creation of a real-time adjustment of Kalman Filter process noise for lithium battery state-of-charge estimation. This work innovates by creating a methodology for adjusting the process (Q) and measurement (R) Kalman Filter noise matrices in real-time. The filter algorithm with this adaptative mechanism achieved an average accuracy of 99.56% in real tests by comparing the estimated battery voltage and measured battery voltage. A cell-balancing strategy was also implemented, capable of guaranteeing the safety and efficiency of the battery pack in all conducted tests. This work presents all the methods, equations, and simulations necessary for the development of a battery management system and applies the system in a practical, real environment. The battery management system hardware and firmware were developed, evaluated, and validated on a battery pack with eight LiFePO4 cells, achieving excellent performance on all conducted tests.

2024

Comparative Analysis of Classical AC/DC Rectifiers for Hydrogen Electrolyzer Applications

Authors
Pedro, D; Araujo, RE; Elhawash, M; Lopes, A;

Publication
2024 IEEE 3rd Industrial Electronics Society Annual On-Line Conference, ONCON 2024

Abstract
This work compares six AC/DC power conversion chain topologies commonly employed by industrial companies for implementing electrolyzers. The main purpose is to help identify the eventual advantages of joining the traditional high-power rectifiers to an additional stage based on DC/DC conversion. The comparison is based on the current ripple, power factor, total harmonic distortion, scalability, and solution complexity. A Simulink model corresponding to each topology was developed to determine comparison criteria. The procedure consists of performing a steady-state analysis of each topology through simulations to obtain the main waveforms and the values of the established criteria and then calculating the scores for each technical solution. The findings indicated that the 24-pulse diode bridge rectifier plus DC-DC without interphase reactor exhibited the best performance. © 2024 IEEE.

2024

Multi-objective planning of community energy storage systems under uncertainty

Authors
Anuradha, K; Iria, J; Mediwaththe, CP;

Publication
Electric Power Systems Research

Abstract

2024

Shaped operating envelopes: Distribution network capacity allocation for market services

Authors
Attarha, A; Noori R.A., SM; Mahmoodi, M; Iria, J; Scott, P;

Publication
Electric Power Systems Research

Abstract

2024

Network-secure aggregator operating regions with flexible dispatch envelopes in unbalanced systems

Authors
Russell, JS; Scott, P; Iria, J;

Publication
Electric Power Systems Research

Abstract

2024

Protection system planning in distribution networks with microgrids using a bi-level multi-objective and multi-criteria optimization technique

Authors
Reiz, C; Leite, JB; Gouveia, CS; Javadi, MS;

Publication
ELECTRIC POWER SYSTEMS RESEARCH

Abstract
Microgrids are able to improve several features of power systems, such as energy efficiencies, operating costs and environmental impacts. Nevertheless, microgrids' protection must work congruently with power distribution protection to safely take all advantages. This research contributes to enable their protection by proposing a bilevel method to simultaneously solve the allocation and coordination problems, where the proposed scheme also includes local protections of distributed energy resources. The uncertainties associated with generation and loads are categorized by the k-means method, as well. The non-dominated sorting genetic algorithm II is employed in the upper-level task to solve the protection and control devices allocation problem with two opposing objectives. In the lower-level task, a genetic algorithm ensures their coordination. Protection devices include reclosers and fuses from the network, and directional relays for the point of common coupling of microgrids, while control devices consist of remote-controlled switches. In contrast to related works, local devices installed at the point of coupling of distributed generation units are considered as well, such as voltage-restrained overcurrent relays and frequency relays. The optimal solution for the decision-maker is achieved by utilizing the compromise programming technique. Results show the importance of solving the allocation and coordination problems simultaneously, achieving up to $25,000 cost savings compared to cases that solve these problems separately. The integrated strategy allows the network operator to select the optimum solution for the protective system and avoid corrective actions afterward. The results also show the viability of the islanding operation depending on the decision maker's criteria.

  • 23
  • 355