Publications by Carmo Vilas Boas

2018

System for automatic gait analysis based on a single RGB-D camera

Authors
Rocha, AP; Pereira Choupina, HMP; Vilas Boas, MD; Fernandes, JM; Silva Cunha, JPS;

Publication
PLOS ONE

Abstract
Human gait analysis provides valuable information regarding the way of walking of a given subject. Low-cost RGB-D cameras, such as the Microsoft Kinect, are able to estimate the 3-D position of several body joints without requiring the use of markers. This 3-D information can be used to perform objective gait analysis in an affordable. portable, and non-intrusive way. In this contribution, we present a system for fully automatic gait analysis using a single RGB-D camera, namely the second version of the Kinect. Our system does not require any manual intervention (except for starting/stopping the data acquisition), since it firstly recognizes whether the subject is walking or not, and identifies the different gait cycles only when walking is detected. For each gait cycle, it then computes several gait parameters, which can provide useful information in various contexts, such as sports, healthcare, and biometric identification. The activity recognition is performed by a predictive model that distinguishes between three activities (walking, standing and marching), and between two postures of the subject (facing the sensor, and facing away from it). The model was built using a multilayer perceptron algorithm and several measures extracted from 3-D joint data, achieving an overall accuracy and F-1 score of 98%. For gait cycle detection, we implemented an algorithm that estimates the instants corresponding to left and right heel strikes, relying on the distance between ankles, and the velocity of left and right ankles. The algorithm achieved errors for heel strike instant and stride duration estimation of 15 +/- 25 ms and 1 +/- 29 ms (walking towards the sensor), and 12 +/- 23 ms and 2 +/- 24 ms (walking away from the sensor ) Our gait cycle detection solution can be used with any other RGB-D camera that provides the 3-D position of the main body joints.

2019

Skin temperature of the foot: comparing transthyretin Familial Amyloid Polyneuropathy and Diabetic Foot patients

Authors
Seixas, A; Vilas Boas, MD; Carvalho, R; Coelho, T; Ammer, K; Vilas Boas, JP; Mendes, J; Silva Cunha, JPS; Vardasca, R;

Publication
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION

Abstract
Skin temperature regulation is dependent on the autonomic nervous system function, which may be impaired in patients with neuropathy. Literature reporting thermographic assessment of patients with established diagnosis of Diabetic Foot (DF) is scarce, but this information is completely absent in patients suffering from Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP). The aim of this study is to compare skin temperature distribution in patients with DF and TTR-FAP. Thermograms of the dorsal and plantar surfaces of twelve neuropathic patients, six with DF and six with TTR-FAP, were assessed and compared. Skin temperature was significantly higher in the diabetic foot group, in both regions of interest. Thermal symmetry values were high, but similar in both groups. The bias between the right and left foot was smaller, with smaller limits of agreement in TTR-FAP patients, suggesting a lower agreement between the temperature of the right and left feet in DF patients.

2019

Full-body motion assessment: Concurrent validation of two body tracking depth sensors versus a gold standard system during gait

Authors
Vilas Boas, MD; Pereira Choupina, HMP; Rocha, AP; Fernandes, JM; Silva Cunha, JPS;

Publication
JOURNAL OF BIOMECHANICS

Abstract
RGB-D cameras provide 3-D body joint data in a low-cost, portable and non-intrusive way, when compared with reference motion capture systems used in laboratory settings. In this contribution, we evaluate the validity of both Microsoft Kinect versions (v1 and v2) for motion analysis against a Qualisys system in a simultaneous protocol. Two different walking directions in relation to the Kinect (towards - WT, and away - WA) were explored. For each gait trial, measures related with all body parts were computed: velocity of all joints, distance between symmetrical joints, and angle at some joints. For each measure, we compared each Kinect version and Qualisys by obtaining the mean true error and mean absolute error, Pearson's correlation coefficient, and optical-to-depth ratio. Although both Kinect v1 and v2 and/or WT and WA data present similar accuracy for some measures, better results were achieved, overall, when using WT data provided by the Kinect v2, especially for velocity measures. Moreover, the velocity and distance presented better results than angle measures. Our results show that both Kinect versions can be an alternative to more expensive systems such as Qualisys, for obtaining distance and velocity measures as well as some angles metrics (namely the knee angles). This conclusion is important towards the off-lab non-intrusive assessment of motor function in different areas, including sports and healthcare.

2019

Automated measures of gait dynamics and camptocormia angle in Parkinson's disease before and after subthalamic deep brain stimulation

Authors
Soares, C; Vilas Boas, MDC; Lopes, EM; Choupina, H; Soares Dos Reis, R; Fitas, D; Cunha, JPS; Monteiro, P; Linhares, P; Rosas, MJSL;

Publication
EUROPEAN JOURNAL OF NEUROLOGY

Abstract
Objective: Axial motor features are common in Parkinson's disease (PD). These include gait impairment and postural abnormalities, such as camptocormia. The response of these symptoms to deep brain stimulation (DBS) is variable and difficult to assess objectively. For the first time, this study analyzes the treatment outcomes of two PD patients with camptocormia that underwent bilateral subthalamic nucleus (STN)-DBS evaluated with disruptive technologies. Patients and methods: Two patients with PD and camptocormia who underwent STN-DBS were included. Gait parameters were quantitatively assessed before and after surgery by using the NeuroKinect system and the camptocormia angle was measured using the camptoapp. Results: After surgery, patient 1 improved 29 points in the UPDRS-III. His camptocormia angle was 68° before and 38° after surgery. Arm and knee angular amplitudes (117.32 ± 7.47 vs 134.77 ± 2.70°; 144.51 ± 7.47 vs 169.08 ± 3.27°) and arm swing (3.59 ± 2.66 vs 5.40 ± 1.76 cm) improved when compared with his preoperative measurements. Patient 2 improved 22 points in the UPDRS-III after surgery. Her camptocormia mostly resolved (47° before to 9° after surgery). Gait analysis revealed improvement of stride length (0.29 ± 0.03 vs 0.35 ± 0.03 m), stride width (18.25 ± 1.16 vs 17.9 ± 0.84 cm), step velocity (0.91 ± 0.57 vs 1.33 ± 0.48 m/s), arm swing (4.51 ± 1.01 vs 7.38 ± 2.71 cm) and arm and hip angular amplitudes (131.57 ± 2.45° vs 137.75 ± 3.18; 100.51 ± 1.56 vs 102.18 ± 1.77°) compared with her preoperative results. Conclusion: The gait parameters and camptocormia of both patients objectively improved after surgery, as assessed by the two quantitative measurement systems. STN-DBS might have a beneficial effect on controlling axial posturing and gait, being a potential surgical treatment for camptocormia in patients with PD. However, further studies are needed to derive adequate selection criteria for this patient population. © 2019 Elsevier B.V.

2019

iHandU: Towards the Validation of a Wrist Rigidity Estimation for Intraoperative DBS Electrode Position Optimization

Authors
Lopes, EM; Sevilla, A; Vilas Boas, MD; Choupina, HMP; Nunes, DP; Rosas, MJ; Oliveira, A; Massano, J; Vaz, R; Cunha, JPS;

Publication
2019 9TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER)

Abstract
DBS surgery is considered for Parkinson's Disease patients when motor complications and consequent quality of life is no longer acceptable on optimal medical therapy prescribed by neurologists. Within the operating room, the electrode placement with the best clinical outcome for the patient is quantitatively assessed via the wrist rigidity assessment. A subjective scale is used, influenced by the neurologists' perception and experience. Our research group has previously designed a novel, comfortable and wireless system aiming to tackle this subjectivity. This system comprised a gyroscope sensor in a textile band, placed in the patients' hand, which communicated its measurement to a Smartphone via Bluetooth. During the wrist rigidity evaluation exam, a signal descriptor was computed from angular velocity (omega) and a polynomial mathematical model was used to classify the signals using a quantitative scale of rigidity improvement. In this present work, we aim to develop models that consider the 3-gyroscope-axes to acquire the omega and the cogwheel rigidity. Our results showed that y-gyroscope-axis remains the best way to classify the rigidity reduction, showing an accuracy of 78% and a mean error of 3.5%. According to previous results, the performance was similar and the decrease of samples to extract the omega features did not compromise system performance. The cogwheel rigidity did not improve the previous model and other gyroscope-axis beyond the y-axis decreased system performance.

2019

Validation of a Single RGB-D Camera for Gait Assessment of Polyneuropathy Patients

Authors
Vilas Boas, MD; Rocha, AP; Pereira Choupina, HMP; Cardoso, MN; Fernandes, JM; Coelho, T; Silva Cunha, JPS;

Publication
SENSORS

Abstract
Motion analysis systems based on a single markerless RGB-D camera are more suitable for clinical practice than multi-camera marker-based reference systems. Nevertheless, the validity of RGB-D cameras for motor function assessment in some diseases affecting gait, such as Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP), is yet to be investigated. In this study, the agreement between the Kinect v2 and a reference system for obtaining spatiotemporal and kinematic gait parameters was evaluated in the context of TTR-FAP. 3-D body joint data provided by both systems were acquired from ten TTR-FAP symptomatic patients, while performing ten gait trials. For each gait cycle, we computed several spatiotemporal and kinematic gait parameters. We then determined, for each parameter, the Bland Altman's bias and 95% limits of agreement, as well as the Pearson's and concordance correlation coefficients, between systems. The obtained results show that an affordable, portable and non-invasive system based on an RGB-D camera can accurately obtain most of the studied gait parameters (excellent or good agreement for eleven spatiotemporal and one kinematic). This system can bring more objectivity to motor function assessment of polyneuropathy patients, potentially contributing to an improvement of TTR-FAP treatment and understanding, with great benefits to the patients' quality of life.