Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Interest
Topics
Details

Details

  • Name

    José Maria Freitas
  • Role

    External Research Collaborator
  • Since

    29th March 2023
  • Nationality

    Portugal
  • Contacts

    +351222094000
    jose.m.freitas@inesctec.pt
Publications

2024

Enhancing ROP plus form diagnosis: An automatic blood vessel segmentation approach for newborn fundus images

Authors
Almeida, J; Kubicek, J; Penhaker, M; Cerny, M; Augustynek, M; Varysova, A; Bansal, A; Timkovic, J;

Publication
RESULTS IN ENGINEERING

Abstract
Background: ROP Plus Form is an eye disease that can lead to blindness, and diagnosing it requires medical experts to manually examine the retinal condition. This task is challenging due to its subjective nature and poor image quality. Therefore, developing automatic tools for Retinal Blood Vessel Segmentation in fundus images could assist healthcare experts in diagnosing, monitoring, and prognosing the disease. Objective: This study focuses on developing a novel pipeline for automatically segmenting retinal blood vessels. The main requirements are that it can correctly identify the blood vessels in fundus images and perform well on different systems used for newborn evaluation. Methods: The pipeline uses different methods, including CIELAB Enhancement, Background Normalization, BellShaped Gaussian Matched Filtering, Modified Top-Hat operation, and a combination of vesselness filtering composed of Frangi and Jerman Filters. The segmentation is done by determining a threshold using the Triangle Threshold algorithm. A novel filter is also proposed to remove the Optical Disc artifacts from the primary segmentation based on the Circular Hough Transform. The segmentation pipeline is combined with different pretrained Convolution Neural Network architectures to evaluate its automatic classification capabilities. Results: The pipeline was tested with newborn fundus images acquired with Clarity RetCam3 and Phoenix ICON systems. The results were compared against annotations from three ophthalmologic experts. Clarity RetCam3 images achieved an accuracy of 0.94, specificity of 0.95, and sensitivity of 0.81, while Phoenix ICON images achieved an accuracy of 0.94, specificity of 0.97, and sensitivity of 0.83. The pipeline was also tested for the DRIVE Database, achieving an accuracy of 0.95, specificity of 0.97, and sensitivity of 0.82. For the classification task, the best results were achieved with the DenseNet121 architecture with an accuracy of 0.946. Conclusion: The segmentation scores were auspicious and confirmed the clinical relevance of the proposed pipeline. It has also proven to have a good generalization performance, essential for easier clinic integration. Finally, preliminary results on using CNNs showed how our work can be used to develop fully automatic tools for diagnosing ROP Plus form disease.