Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Interest
Topics
Details

Details

  • Name

    Anna Loesch
  • Role

    External Research Collaborator
  • Since

    15th September 2017
  • Nationality

    Alemanha
  • Contacts

    +351222094000
    anna.loesch@inesctec.pt
Publications

2016

A Novel Portable, Low-Cost Kinect-Based System for Motion Analysis in Neurological Diseases

Authors
Silva Cunha, JPS; Rocha, AP; Pereira Choupina, HMP; Fernandes, JM; Rosas, MJ; Vaz, R; Achilles, F; Loesch, AM; Vollmar, C; Hartl, E; Noachtar, S;

Publication
2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)

Abstract
Many neurological diseases, such as Parkinson's disease and epilepsy, can significantly impair the motor function of the patients, often leading to a dramatic loss of their quality of life. Human motion analysis is regarded as fundamental towards an early diagnosis and enhanced follow-up in this type of diseases. In this contribution, we present NeuroKinect, a novel system designed for motion analysis in neurological diseases. This system includes an RGB-D camera (Microsoft Kinect) and two integrated software applications, KiT (KinecTracker) and KiMA (Kinect Motion Analyzer). The applications enable the preview, acquisition, review and management of data provided by the sensor, which are then used for motion analysis of relevant events. NeuroKinect is a portable, low-cost and markerless solution that is suitable for use in the clinical environment. Furthermore, it is able to provide quantitative support to the clinical assessment of different neurological diseases with movement impairments, as demonstrated by its usage in two different clinical routine scenarios: gait analysis in Parkinson's disease and seizure semiology analysis in epilepsy.

2016

NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification

Authors
Cunha, JPS; Choupina, HMP; Rocha, AP; Fernandes, JM; Achilles, F; Loesch, AM; Vollmar, C; Hartl, E; Noachtar, S;

Publication
PLOS ONE

Abstract
Epilepsy is a common neurological disorder which affects 0.5-1% of the world population. Its diagnosis relies both on Electroencephalogram (EEG) findings and characteristic seizure -induced body movements - called seizure semiology. Thus, synchronous EEG and (2D) video recording systems (known as Video-EEG) are the most accurate tools for epilepsy diagnosis. Despite the establishment of several quantitative methods for EEG analysis, seizure semiology is still analyzed by visual inspection, based on epileptologists' subjective interpretation of the movements of interest (MOIs) that occur during recorded seizures. In this contribution, we present NeuroKinect, a low-cost, easy to setup and operate solution for a novel 3Dvideo-EEG system. It is based on a RGB-D sensor (Microsoft Kinect camera) and performs 24/7 monitoring of an Epilepsy Monitoring Unit (EMU) bed. It does not require the attachment of any reflectors or sensors to the patient's body and has a very low maintenance load. To evaluate its performance and usability, we mounted a state-of-the-art 6-camera motion-capture system and our low-cost solution over the same EMU bed. A comparative study of seizure-simulated MOIs showed an average correlation of the resulting 3D motion trajectories of 84.2%. Then, we used our system on the routine of an EMU and collected 9 different seizures where we could perform 3D kinematic analysis of 42 MOIs arising from the temporal (TLE) (n = 19) and extratemporal (ETE) brain regions (n = 23). The obtained results showed that movement displacement and movement extent discriminated both seizure MOI groups with statistically significant levels (mean = 0.15 m vs. 0.44 m, p<0.001; mean = 0.068 m(3) vs. 0.14 m(3), p< 0.05, respectively). Furthermore, TLE MOIs were significantly shorter than ETE (mean = 23 seconds vs 35 seconds, p< 0.01) and presented higher jerking levels (mean = 345 ms(-3) vs 172 ms(-3), p< 0.05). Our newly implemented 3D approach is faster by 87.5% in extracting body motion trajectories when compared to a 2D frame by frame tracking procedure. We conclude that this new approach provides a more comfortable (both for patients and clinical professionals), simpler, faster and lower-cost procedure than previous approaches, therefore providing a reliable tool to quantitatively analyze MOI patterns of epileptic seizures in the routine of EMUs around the world. We hope this study encourages other EMUs to adopt similar approaches so that more quantitative information is used to improve epilepsy diagnosis.