2014
Autores
Couto, M; Carçao, T; Cunha, J; Fernandes, JP; Saraiva, J;
Publicação
PROGRAMMING LANGUAGES, SBLP 2014
Abstract
The use of powerful mobile devices, like smartphones, tablets and laptops, is changing the way programmers develop software. While in the past the primary goal to optimize software was the run time optimization, nowadays there is a growing awareness of the need to reduce energy consumption. This paper presents a technique and a tool to detect anomalous energy consumption in Android applications, and to relate it directly with the source code of the application. We propose a dynamically calibrated model for energy consumption for the Android ecosystem that supports different devices. The model is used as an API to monitor the application execution: first, we instrument the application source code so that we can relate energy consumption to the application source code; second, we use a statistical approach, based on fault-localization techniques, to localize abnormal energy consumption in the source code.
2014
Autores
Guerreiro, CA; Saraiva, JT; Sousa, JC; Mendes, VT;
Publicação
International Conference on the European Energy Market, EEM
Abstract
With the advent of restructuring, generation companies have to plan the operation of their stations in order to maximize their profits. This is very relevant for companies having a large share of hydro stations, and even more if these stations have pumping capacity. This paper describes a model to plan the operation of a set of hydro stations eventually installed in cascade and admitting that some of them are pumping stations. Once a first set of operation orders is obtained using a Genetic Algorithm, their generation/load values are included in the expected market selling/buying curves and the hourly prices are updated. These prices are then used to refine the operation orders originating an iterative process so that hydro stations are price makers. The paper includes results for a hydro system in order to illustrate the application of the developed approach. © 2014 IEEE.
2014
Autores
Fabian, L; Mathesz, A; Valkai, S; Alexandre, D; Marques, PVS; Ormos, P; Wolff, EK; Der, A;
Publicação
BIOPHYSICAL JOURNAL
Abstract
2014
Autores
Sequeira, LM; Morgado, L; Pires, ES;
Publicação
Procedia Technology
Abstract
2014
Autores
Moreira, AHJ; Queirós, S; Fonseca, J; Rodrigues, PL; Rodrigues, NF; Vilaça, JL;
Publicação
SeGAH 2014 - IEEE 3rd International Conference on Serious Games and Applications for Health, Books of Proceedings
Abstract
Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors' accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application's satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.
2014
Autores
Silva, SO; Auguste, JL; Jamier, R; Rougier, S; Baptista, JM; Santos, JL; Roy, P; Frazao, O;
Publicação
OPTICAL ENGINEERING
Abstract
A multimodal interferometer based on a new microstructured fiber tip is proposed for detection of the evaporation process of acetone. The new geometry consists of a capillary tube in which an offset Ge-doped core is fused and spliced at the end of a single-mode fiber. The fiber tip sensor structure was immersed in liquid acetone and the evaporation process of acetone was monitored in real time. Due to the refractive index variation of the external medium with increasing temperature, a short detection time of similar to 1 s was achieved. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.