2015
Autores
Costa, T; Leal, JP;
Publicação
LANGUAGES, APPLICATIONS AND TECHNOLOGIES, SLATE 2015
Abstract
In the previous research the authors developed a family of semantic measures that are adaptable to any semantic graph, being automatically tuned with a set of parameters. The research presented in this paper extends this approach by also tuning the graph. This graph reduction procedure starts with a disconnected graph and incrementally adds edge types, until the quality of the semantic measure cannot be further improved. The validation performed used the three most recent versions of WordNet and, in most cases, this approach improves the quality of the semantic measure.
2015
Autores
Dias, A; Campos, P; Garrido, P;
Publicação
ADVANCES IN ARTIFICIAL ECONOMICS
Abstract
2015
Autores
Goncalves, J; Batista, J; Novo, A;
Publicação
CONTROLO'2014 - PROCEEDINGS OF THE 11TH PORTUGUESE CONFERENCE ON AUTOMATIC CONTROL
Abstract
In this paper it is described the prototyping of an instrumented chair that allows to fully-automate the "Timed Up and Go" and "30-Second Chair Stand" tests assessment. The presented functional chair prototype is a low cost approach that uses inexpensive sensors and the Arduino platform as the data acquisition board, with its software developed resorting to LabVIEW. The "Timed up and go test" consists in measuring the time spent in the task execution of standing up from a chair, walk three meters with a maximum speed without running, turn a cone and going back to the initial position. The "30-Second Chair Stand" test consists in the count of the number of completed chair stands in 30 seconds. It are agility and strength tests easy to setup and execute although they lack of repeatability, whenever the measures are taken manually, due to the rough errors that are introduced.
2015
Autores
Coelho, L; de Almeida, JMMM; Santos, JL; Viegas, D;
Publicação
APPLIED OPTICS
Abstract
A study of a sensor for hydrogen (H-2) detection based on fiber Bragg gratings coated with palladium (Pd) with self-temperature compensation is presented. The cladding around the gratings was reduced down to 50 mu m diameter by a chemical etching process. One of the gratings was left uncoated, and the other was coated with 150 nm of Pd. It was observed that palladium hydride has unstable behavior in environments with high humidity level. A simple solution to overcome this problem based on a Teflon tape is presented. The sensing device studied was able to respond to H-2 concentrations in the range 0%-1% v/v at room temperature and atmospheric pressure, achieving sensitivities larger than 20 pm/% v/v. Considering H-2 concentrations in nitrogen up to 1%, the performance of the sensing head was characterized for different thicknesses of Pd coating ranging from 50 to 200 nm. (C) 2015 Optical Society of America
2015
Autores
Goncalves, RP; Augusto, AB; Correia, ME;
Publicação
2015 10TH IBERIAN CONFERENCE ON INFORMATION SYSTEMS AND TECHNOLOGIES (CISTI)
Abstract
Handwritten signature recognition is still the most widely accepted method to validate paper based documents. However, in the digital world, there is no readymade way to distinguish a real handwritten signature on a scanned document from a forged copy of another signature made by the same person on another document that is simply "pasted" into the forged document. In this paper we describe how we are using the touch screen of smartphones or tablets to collect handwritten signature images and associated biometric markers derived from the motion direction of handwritten signatures that are made directly into the device touchscreen. These time base biometric markers can then be converted into signaling time waves, by using the dragging or lifting movements the user makes with a touch screen omnidirectional tip stylus, when he handwrites is signature at the device touchscreen. These time/space signaling time waves can then be converted into a biometric bit stream that can be matched with previously enrolled biometric markers of the user's handwritten signature. In this paper we contend that the collection of these simple biometric features is sufficient to achieve a level of user recognition and authentication that is sufficient for the majority of online user authentication and digital documents authenticity.
2015
Autores
Ferreira, P; Malheiro, B; Guedes, P; Silva, M;
Publicação
Robotic Sailing 2014
Abstract
This paper describes the environmental monitoring / regatta beacon buoy under development at the Laboratory of Autonomous Systems (LSA) of the Polytechnic Institute of Porto. On the one hand, environmentalmonitoring of open water bodies in real or deferred time is essential to assess and make sensible decisions and, on the other hand, the broadcast in real time of position, water and wind related parameters allows autonomous boats to optimise their regatta performance. This proposal, rather than restraining the boats autonomy, fosters the development of intelligent behaviour by allowing the boats to focus on regatta strategy and tactics. The Nautical and Telemetric Application (NAUTA) buoy is a dual mode reconfigurable system that includes communications, control, data logging, sensing, storage and power subsystems. In environmental monitoring mode, the buoy gathers and stores data from several underwater and above water sensors and, in regatta mode, the buoy becomes an active course mark for the autonomous sailing boats in the vicinity. During a race, the buoy broadcasts its position, together with the wind and the water current local conditions, allowing autonomous boats to navigate towards and round the mark successfully. This project started with the specification of the requirements of the dual mode operation, followed by the design and building of the buoy structure. The research is currently focussed on the development of the modular, reconfigurable, open source-based control system. The NAUTA buoy is innovative, extensible and optimises the on board platform resources.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.