Empirical mode decomposition for self-mixing Doppler signals of hemodynamic optical probes

Autores
Pereira, T; Vaz, P; Oliveira, T; Santos, I; Pereira, HC; Almeida, V; Correia, C; Cardoso, J;

Publicação
PHYSIOLOGICAL MEASUREMENT

Abstract
A new type of optical probe based on laser Doppler self-mixing technology, for a truly non-contact measurement in a single location, and extraction of the temporal features of the distension wave in the arterial wall, was developed. The monitoring of temporal features allows the assessment of cardiovascular function when measurement is carried out at the carotid artery. An algorithm based on the short-time Fourier transform and empirical mode decomposition was applied to the test setup self-mixing signals for the determination of waveform features, with an accuracy of a few milliseconds and a root mean square error less than 3 ms. In vivo testing signals show great consistency in the measured pulse pressure waveform.

2017

Validation of a low intrusiveness heart rate sensor for stress assessment

Autores
Pereira, T; Almeida, PR; Cunha, JPS; Aguiar, A;

Publicação
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS

Abstract
Heart rate variability (HRV) analysis has been used as a quantitative marker of the autonomous nervous system activity to measure mental stress. Wearable sensors have been emerging as a solution to collect HRV data for stress assessment in a real context, however such studies raise additional requirements. The wearable system must be minimally obtrusive to allow the subjects to perform their tasks without interference, and inconspicuous to avoid the anxiety associated with wearing medical devices in public. The purpose of this study was to quantify the accuracy trade-off in the use of a chest band heart rate sensor that is less intrusive and less costly than a wearable electrocardiogram (ECG). The HRV metrics extracted from a chest band heart rate monitor, Zephyr HxM (TM) (Zph (TM)), were compared with those extracted from an ECG certified medical device, Vital Jacket (TM) (VJ (TM)). The two systems were worn simultaneously. under laboratory conditions by a population of 14 young and healthy subjects, aged 20 to 26 years, under the stress induced by the Trier Social Stress Test (TSST) procedure. The results showed a mean difference between RR intervals of 9 ms; a. root-mean square error. (RMSE) of less than 8% and. a Pearson's correlation higher than 0.946, considering all TSST phases. In the HRV analysis, the average of all normal intervals (AVNN) showed errors less than 2% between the two systems with a correlation higher than 0.99 for all TSST phases. We thus conclude that the used chest band sensor represents an alternative to the current wearable medical devices to monitor RR intervals, and could be used for mental stress monitoring similar to the TSST protocol.

2013

Bioimpedance parameters as a risk factor to assess pine decay: An innovative approach to the diagnosis of plant diseases

Autores
Borges, E; Sequeira, M; Cortez, AFV; Pereira, HC; Pereira, T; Almeida, V; Vasconcelos, TM; Duarte, IM; Nazare, N; Cardoso, J; Correia, C;

Publicação
BIODEVICES 2013 - Proceedings of the International Conference on Biomedical Electronics and Devices

Abstract
Electrical impedance spectroscopy, EIS, has been proving efficacy and utility in a wide range of areas, from the characterization of biological tissues to living organisms. Several commercial solutions, with high precision and resolution, are available. Nonetheless, the typical equipments are expensive, unfeasible for in vivo and in field applications and unspecific for concrete applications. These features, together with the lately demands in the vegetal field, fundament this work. Actually, the fast spread of asymptomatic forest diseases, with no cure available to date, such as the pinewood disease, PWD, constitute a problem of economical and forestall huge proportions. Herein is proposed a portable EIS system, for biological applications, able to perform AC current or voltage scans within a selectable frequency range. The procedure and the results obtained for a population of 24 young pine trees (Pinus pinaster Aiton) are also presented. Pine trees were kept in a controlled environment and were inoculated with the nematode (Bursaphelenchus xylophilus Nickle), that causes the PWD, and also with bark beetles (Tomicus destruens Wollaston). Some degree of discrimination between different physiological states was achieved. These results may constitute a first innovative approach to the diagnosis of such types of diseases.

2013

New optical probe approach using mixing effect in planar photodiode for biomedical applications

Autores
Pereira, T; Vaz, P; Oliveira, T; Santos, I; Leal, A; Almeida, V; Pereira, H; Correia, C; Cardoso, J;

Publicação
OPTICAL SENSORS 2013

Abstract
The laser diode self-mixing technique is a well-known and powerful interferometric technique that has been used in biomedical applications, namely for the extraction of cardiovascular parameters. However, to construct an optical probe using the self-mixing principle which is able to acquire signals in the human carotid artery, some problems are expected. The laser diode has a small aperture area, which means that, for physiological sensing purposes, it can be considered as a point-like detector. This feature imparts difficulties to quality recording of physiological signals since the number of photons collected and mixed in the cavity of the photodiode is very small. In order to overcome this problem, a new mixing geometry based on an external large area planar photodiode (PD) is used in the probe, enabling a much larger number of photons to be collected, hence improving the quality of the signal. In this work, the possibility to obtain the mixing effect outside the laser cavity using an external photodetector, such as a planar photodiode, is demonstrated. Two test benches were designed, both with of two reflectors. The first one, which reflects the light beam with the same frequency of the original one is fixed, and the second one, is movable, reflecting the Doppler shifted light to the photodetector. The first test bench has a fixed mirror in front of the movable mirror, creating an umbra and penumbra shadow above the movable mirror. To avoid this problem, another test bench was constructed using a wedged beam splitter (WSB) instead of a fixed mirror. This new assembly ensures the separation of a single input beam into multiple copies that undergo successive reflections and refractions. Some light waves are reflected by the planar surface of WSB, while other light beams are transmitted through the WSB, reaching the movable mirror. Also in this case, the movable mirror reflects the light with a Doppler frequency shift, and the PD receives both beams. The two test benches were designed to demonstrate that it is possible to obtain mixing effect outside the laser cavity, using a planar photodiode. The Doppler spectrograms from the signals acquired in the test benches show that the signal frequency changes along time which correspond to the modulus of the derivative of the mirror movement, as expected in the self-mixing signals. Nevertheless, the test bench A showed better results than the test bench B. This fact probably results from the attenuation that the original beam suffers in each reflection and refraction in the WBS. Tests developed in the test benches opened the possibility to construct a probe that uses a planar photodiode with a large area to collect medical signals, and improve the quality of the acquisition with a better SNR.

2014

Pine Decay Assessment by Means of Electrical Impedance Spectroscopy

Autores
Borges, E; Sequeira, M; Cortez, A; Pereira, HC; Pereira, T; Almeida, V; Vasconcelos, T; Duarte, I; Nazare, N; Cardoso, J; Correia, C;

Publicação
BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES (BIOSTEC 2013)

Abstract
Plant diseases, such as the pinewood disease, PWD, have become a problem of economical and forestall huge proportions. These diseases, that are asymptomatic and characterized by a fast spread, have no cure developed to date. Besides, there are no technical means to diagnose the disease in situ, without causing tree damage, and help to assist the forest management. Herein is proposed a portable and non-damage system, based on electrical impedance spectroscopy, EIS, for biological applications. In fact, EIS has been proving efficacy and utility in wide range of areas. However, although commercial equipment is available, it is expensive and unfeasible for in vivo and in field applications. The developed EIS system is able to perform AC current or voltage scans, within a selectable frequency range, and its effectiveness in assessing pine decay was proven. The procedure and the results obtained for a population of 24 young pine trees (Pinus pinaster Aiton) are presented. Pine trees were kept in a controlled environment and were inoculated with the nematode (Bursaphelenchus xylophilus Nickle), that causes the PWD, and also with bark beetles (Tomicus destruens Wollaston). The obtained results may constitute a first innovative approach to the diagnosis of such types of diseases.

2013

Comparison of Low-Cost and Noninvasive Optical Sensors for Cardiovascular Monitoring

Autores
Pereira, T; Oliveira, T; Cabeleira, M; Pereira, H; Almeida, V; Cardoso, J; Correia, C;

Publicação
IEEE SENSORS JOURNAL

Abstract
New optical probes are developed for carotid distention waveform measurements, in order to assess the risk of cardiovascular diseases. The probes make use of two distinct photodetectors: planar and avalanche photodiodes. Their performance is compared for visible and infrared (IR) light wavelengths. The test setup designed for the evaluation of the probes simulates the fatty deposits commonly seen in the obese people, between skin and the artery. The performed tests show that the attenuation of the signal is lower for the IR light, with higher penetration and better resolution in the captured distension waveform, with higher definition in morphological features on the wave and higher signal-to-noise ratio when compared to the visible source signals. The probes show good overall performance in the test setup with a root mean square error lower than 8%. In vivo, the IR probes allow easier waveform detection, even more relevant with the increasing deposit structures.