Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Catarina Silva Monteiro

2023

Optical fiber flowmeter based on graphene oxide coated michelson interferometer

Autores
Monteiro, CS; Ferreira, M; Mendes, JP; Coelho, LCC; Silva, SO; Frazao, O;

Publicação
SENSORS AND ACTUATORS A-PHYSICAL

Abstract
Measuring gas and liquid flow rate is paramount in various scientific and industrial applications. This work presents an optical fiber flowmeter based on a graphene oxide (GO) coated Michelson interferometer. The interferometer is fabricated using a long-period fiber grating (LPFG) followed by a GO-coated single-mode fiber (SMF). By radiating the GO coating, it experiences photothermic effect that induces local heating of the film. This results in a variation in the effective refractive index in the cladding modes, which induces a phase shift on the interferometer spectrum. When a gas flow is introduced near the coated fiber, the hot-wire region will experience a reduction in temperature proportional to the flow rate. The flowmeter exhibited a linear wavelength shift to the flow rate with an absolute sensitivity of 17.4 +/- 0.8 pm/(L.min-1) for gas flow rates between 2 and 8 L/ min. Furthermore, the dynamic response of the sensor was studied, attaining a maximum response time of 1.1 +/- 0.4 s

2023

Optical Fiber Flowmeter Based on a Michelson Interferometer

Autores
Monteiro, CS; Ferreira, M; Mendes, JP; Coelho, LCC; Silva, S; Frazão, O;

Publicação
EPJ Web of Conferences

Abstract
In this work, an optical fiber flowmeter based on a Michelson interferometer is presented. The Michelson interferometer uses a long period fiber grating (LPFG) to couple light to the cladding modes followed by a section of a GO-coated single mode fiber (SMF). By radiating the GO thin film, it will increase its temperature changing the effective refractive index of the optical cavity of the Michelson interferometer. By placing the sensor on a gas flow, its temperature surface will decrease in a proportional manner to the flow rate. The sensor was studied in both static and dynamic dry nitrogen flow, attaining an absolute sensitivity of 17.4 ± 0.8 pm/(L.min-1) and a maximum response time of 1.1 ± 0.4 s.

  • 5
  • 5