Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por CAP

2020

Tuning of Fiber Optic Surface Reflectivity through Graphene Oxide-Based Layer-by-Layer Film Coatings

Autores
Monteiro, CS; Raposo, M; Ribeiro, PA; Silva, SO; Frazao, O;

Publicação
PHOTONICS

Abstract
The use of graphene oxide-based coatings on optical fibers are investigated, aiming to tune the reflectivity of optical fiber surfaces for use in precision sensing devices. Graphene oxide (GO) layers are successfully deposited onto optical fiber ends, either in cleaved or hollow microspheres, by mounting combined bilayers of polyethylenimine (PEI) and GO layers using the Layer-by-Layer (LbL) technique. The reflectivity of optical fibers coated with graphene oxide layers is investigated for the telecom region allowing to both monitor layer growth kinetics and cavity characterization. Tunable reflective surfaces are successfully attained in both cleaved optical fibers and hollow microsphere fiber-based sensors by simply coating them with PEI/GO layers through the LbL film technique.

2020

Curvature detection in a medical needle using a Fabry-Perot cavity as an intensity sensor

Autores
Novais, S; Silva, SO; Frazao, O;

Publicação
MEASUREMENT

Abstract
The use of optical sensors inside the needle can improve targeting precision and can bring real-time information about the location of the needle tip if necessary, since a needle bends through insertion into the tissue. Therefore, the precise location of the needle tip is so important in percutaneous treatments. In the current experiment, a fiber sensor based on a Fabry-Perot (FP) cavity is described to measure the needle curvature. The sensor is fabricated by producing an air bubble between two sections of multimode fiber. The needle with the sensor therein was attached at one end and deformed by the application of movements. The sensor presents a sensitivity of -0.152 dB/m(-1) to the curvature measurements, with a resolution of 0.089 m(-1). The sensory structure revealed to be stable, obtaining a cross-sensitivity to be 0.03 m(-1)/degrees C.

2020

Curvature Sensor Based on a Long-Period Grating in a Fiber Ring Resonator Interrogated by an OTDR

Autores
Magalhaes, R; Silva, S; Frazao, O;

Publicação
PHOTONIC SENSORS

Abstract
The proposed technique demonstrates a fiber ring resonator interrogated by an optical time domain reflectometer (OTDR), for intensity sensing. By using this methodology, a cavity round trip time of 2.85 mu s was obtained. For a proof of concept, a long-period grating was inserted in the resonant cavity operating as a curvature sensing device. A novel signal processing approach was outlined, regarding to the logarithmic behavior of the OTDR. Through analyzing the experimental results, an increase in the measured sensitivities was obtained by increasing applied bending. With curvatures performed from 1.8 m(-1) to 4.5 m(-1), the sensitivity values ranged from 2.94 dB center dot km(-1) to 5.15 dB center dot km(-1). In its turn, the sensitivities obtained presented a linear behavior when studied as a function of the applied curvature, following a slope of 0.86x10(-3) dB. The advantages of applying this technique were also discussed, demonstrating two similar fiber rings multiplexed in a series of configurations.

2020

Detection of the Crystallization Process of Paracetamol with a Multi-Mode Optical Fiber in a Reflective Configuration

Autores
Soares, L; Novais, S; Ferreira, A; Frazao, O; Silva, S;

Publicação
SENSORS

Abstract
A configuration of a refractometer sensor is described with the aim of optically detecting the crystallization process of paracetamol. The developed sensing head is based on a conventional cleaved multi-mode fiber. The fiber tip sensor structure was submitted to contact with the liquid of interest (paracetamol fully dissolved in 40% v/v of ethanol/water) and the crystallization process of paracetamol, induced with continued exposure to air, was monitored in real time.

2020

Magnetostriction assessment with strain gauges and fiber bragg gratings

Autores
Linhares, CC; Santo, JE; Teixeira, RR; Coutinho, CP; Tavares, SMO; Pinto, M; Costa, JS; Mendes, H; Monteiro, CS; Rodrigues, AV; Frazão, O;

Publicação
EAI Endorsed Transactions on Energy Web

Abstract
Power transformers have an imperative role in the future developments of the electrical grids. Treated as crucial assets for transportation and distribution of electrical energy, transformers are currently being studied regarding to the integration of technologies aiming to diagnose problems and monitoring data of electrical power grid. Furthermore, environmental noise pollution has gained importance, especially in active units of the power grid, located near consumers, such as transformers. Transformers noise can be classified according to its source: core, windings and cooling. This study addresses an experimental characterization of one of the main causes of transformers core noise-magnetostriction of electrical steel. An evaluation of magnetostriction properties of electrical steel, including resistive strain gauges and Fiber Bragg Gratings (FBGs) measurements with an Epstein frame, are presented and discussed. The magnetic flux density influence on hysteretic strain behavior of magnetostriction was evaluated, as well as the effect of a clamping load on core joints. Nowadays, optical interrogators for Bragg gratings have a high acquisition frequencies and wavelength sensitivity when compared to former optical interrogation systems, allowing to evaluate physical phenomena without electromagnetic interference and with equivalent resolution of conventional strain gauges. © 2019 Cassiano C. Linhares et al.

2020

Hollow microsphere combined with optical harmonic Vernier effect for strain and temperature discrimination

Autores
Gomes, AD; Ferreira, MS; Bierlich, J; Kobelke, J; Rothhardt, M; Bartelt, H; Frazao, O;

Publicação
OPTICS AND LASER TECHNOLOGY

Abstract
Achieving a new generation of enhanced sensors requires the development of structures that result from the fusion of different concepts and effects. In this paper, we combine a special strain sensing structure with an optical sensitivity magnification, through harmonics of the Vernier effect. The recently demonstrated harmonics of the Vernier effect result from increasing the optical path length (OPL) of one of two interferometers by multiple times the OPL of the other interferometer. The effect generates higher magnification factors, proportional to the order of the harmonics. The sensing structure is demonstrated for strain and temperature discrimination, allowing compensation for temperature fluctuations. We explore the complex case of the optical Vernier effect in series, where both interferometers are used as sensing interferometers (no reference interferometer is used). Our results also suggest that the magnification enhancement provided by harmonics of the Vernier effect for a configuration in series is the same as for a configuration in parallel: the magnification factor increases proportionally to the order of the harmonics.

  • 39
  • 230