Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por CAP

2012

Study and calibration of FBG sensors for the accurate strain monitoring of COPV

Autores
Pereira, G; Faria, H; Frias, C; Frazao, O; Marques, AT;

Publicação
ECCM 2012 - Composites at Venice, Proceedings of the 15th European Conference on Composite Materials

Abstract
In this research programme methodologies to improve the accuracy in the results measured with embedded fibre Bragg gratings (FBG) sensors were studied and implemented in order to produce a composite overwrapped pressure vessel (COPV) prototype that incorporate a non-destructive sensing technologies. Using a carbon/epoxy prepreg system, test specimens were manufactured with longitudinally embedded FBG sensors. The combined behaviour of the sensors and the host material was characterized and a calibration rule (correction factor) was determined for the chosen material. The consistency of the results with both theoretical and empirical assumptions suggests that the proposed method is applicable to a wide range of FBG sensors and host materials. In this paper, the experimental setup and procedure used to assess to the calibration rule is addressed and further detailed.

2012

Multimode interference tapered fiber refractive index sensors

Autores
Biazoli, CR; Silva, S; Franco, MAR; Frazao, O; Cordeiro, CMB;

Publicação
APPLIED OPTICS

Abstract
Real-time monitoring of the fabrication process of tapering down a multimode-interference-based fiber structure is presented. The device is composed of a pure silica multimode fiber ( MMF) with an initial 125 mu m diameter spliced between two single-mode fibers. The process allows a thin MMF with adjustable parameters to obtain a high signal transmittance, arising from constructive interference among the guided modes at the output end of the MMF. Tapered structures with waist diameters as low as 55 mu m were easily fabricated without the limitation of fragile splices or difficulty in controlling lateral fiber alignments. The sensing device is shown to be sensitive to the external environment, and a maximum sensitivity of 2946 nm/refractive index unit in the refractive index range of 1.42-1.43 was attained. (c) 2012 Optical Society of America

2012

Temperature independent torsion sensor using a high-birefringent Sagnac loop interferometer

Autores
Silva, RM; Ferreira, MS; Frazao, O;

Publicação
OPTICS COMMUNICATIONS

Abstract
A high-birefringent (Hi-Bi) Sagnac loop interferometer for torsion measurement is demonstrated. The sensing head is formed by a section of standard single mode fiber spliced between the output ports of a Hi-Bi coupler at 3 dB. The sensing configuration is characterized in torsion, temperature and strain. The results obtained indicate the viability of a torsion sensor independent of the temperature and strain cross-sensitivity effects. Additionally, in the proposed configuration all measurements are performed without the need of a polarization controller, a device most often required in standard Sagnac loops applied for sensing.

2012

Smart sensors/actuators for biomedical applications: Review

Autores
Ponmozhi, J; Frias, C; Marques, T; Frazao, O;

Publicação
MEASUREMENT

Abstract
This paper reflects on review of smart sensor activities for biomedical applications. The rise of biotechnology has provided innovative development of new therapies and detection methods for life threatening diseases. As a worldwide research focus, there is especially a strong interest in the use of microsystems in health care, particularly as smart implantable devices. Recent years have seen an increasing activity of hip and knee replacement and other type of implants, which are some of the most frequently performed surgical procedures in the world. Loosening of hip prosthesis is the dominant issue for many patients who undergo a hip arthroplasty. Artificial joints are subject to chronic infections associated with bacterial biofilms, which only can be eradicated by the traumatic removal of the implant followed by sustained intravenous antibiotic therapy. This review focuses on the clinical experience using all kinds of smart implants like orthopedic implants instrumented with strain gauges, retina implant system using image sensors. Technical design improvements will enhance function, quality of life, and longevity of total knee arthroplasty and all other kind of implants. Application of biocompatible nanomaterials in implantable biosensors for continuous monitoring of metabolites is an area of sustained scientific and technological interests. Crown Copyright

2012

Interferometer based on a d-shape chaotic optical fiber for measurement of multiparameters

Autores
Silva, S; Coelho, L; Roy, P; Frazao, O;

Publicação
Photonic Sensors

Abstract
An interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters was proposed. The sensing structure relied on a D-shape fiber section spliced in between two singlemode fibers and interrogated in transmission. The optical spectrum was composed by multiple interference loss peaks, which were sensitive to the refractive index, temperature and strain-maximum sensitivities of 95.2 nm/RIU, 10.5 pm/ and -3.51 pm/µe, respectively, could be achieved. © The Author(s) 2012.

2012

Multimode interference in outer cladding large-core, air-clad photonic crystal fiber

Autores
Coelho, L; Kobelke, J; Schuster, K; Frazao, O;

Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
It is described a large-core air-clad photonic crystal fiber-based sensing structure using the outer cladding as a light guide, which is highly sensitive to refractive index. The sensing head is based on multimodal interference, and relies on a single mode/large-core air-clad photonic crystal fiber/single mode fiber configuration. Using this configuration and controlling the light to travel in a segment of the outer cladding multimode fiber, it was possible to implement a sensing head and the results were obtained independently from variations of temperature, strain and refractive index. (c) 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:10091011, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26726

  • 138
  • 241