Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por CAP

2014

Advanced experiments with an Erbium doped fiber laser

Autores
Marques, PVS; Marques, MB; Rosa, CC;

Publicação
12TH EDUCATION AND TRAINING IN OPTICS AND PHOTONICS CONFERENCE

Abstract
This communication describes an optical hands-on fiber laser experiment aimed at advanced college courses. Optical amplifiers and laser sources represent very important optical devices in numerous applications ranging from telecommunications to medicine. The study of advanced photonics experiments is particularly relevant at undergraduate and master level. This paper discusses the implementation of an optical fiber laser made with a cavity built with two tunable Bragg gratings. This scheme allows the students to understand the laser working principles as a function of the laser cavity set-up. One or both of the gratings can be finely tuned in wavelength through applied stress; therefore, the degree of spectral mismatch of the two gratings can be adjusted, effectively changing the cavity feedback. The impact of the cavity conditions on the laser threshold, spectrum and efficiency is analyzed. This experiment assumes that in a previous practice, the students should had already characterized the erbium doped fiber in terms of absorption and fluorescent spectra, and the spectral gain as a function of pump power.

2014

High Speed All Optical Logic Operations Utilizing the Protein Bacteriorhodopsin

Autores
Fabian, L; Mathesz, A; Valkai, S; Alexandre, D; Marques, PVS; Ormos, P; Wolff, EK; Der, A;

Publicação
BIOPHYSICAL JOURNAL

Abstract

2014

Real-time dosimeter targeted to nuclear applications

Autores
Correia, A; Rosa, CC; Santos, PMP; Falcao, AN; Lorentz, K;

Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
An intrinsic fiber optic dosimeter (FOD) targeted to nuclear applications is presented. The proposed real-time dosimeter provides dose information based on the historic record over time of the effects of ionizing radiation on single-and multi-mode pure silica fibers, and also on PMMA plastic fibers. The effect of Co-60 gamma irradiation on optical links based on silica and plastic fibers were assessed, considering thermal environment effects over a wide range of variation of the operating parameters. Cerenkov radiation and radiation-induced absorption effects were in focus. The corresponding distortion and spectral transmission degradation were evaluated over wide range of the operating parameters. Radiation induced attenuation (RIA) has shown a spectral band dependent behaviour up to 840 Gy dose levels. The performance of different fibers was assessed against the performance of non-irradiated fibers. From the measurements of dose rate and total dose imparted by ionizing radiation in the fibers we verified that fibers with radiation resistance issues showed wavelength-dependent radiation sensitivity increasing with dose rate. Upon evaluation of correlations between the total dose, the induced loss at various dose rates and different wavelengths, it was concluded that intrinsic fiber dosimeters can be used for dose rates in the range 4 - 28 Gy/min., typical of severe radiation environments.

2014

FEM simulation and experimental determination of the temperature profile of nanoparticles excited by laser radiation

Autores
Rodrigues, NFG; Rosa, CC; Coelho, JMP;

Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
Cancer cells can be easily killed when they reach a temperature above 40 degrees. This is known as hyperthermia and the incorporation of nanoparticles (NPs) is helpful to locally rise the temperature. The local heating of NPs could also be used to deliver drugs encapsulated in a specific location inside a body. To achieve the local heating it is necessary to know the temperature profile of the NPs when excited by laser radiation. The COMSOL software was used to simulate the temperature profile of the NPs in an aqueous solution (the cells are mainly composed of water). An analysis is made regarding the temperature rise for different irradiation parameters, NPs concentration and the corresponding potential of locally affecting cancerous cells without significantly affecting adjacent healthy cells.

2014

Design and optimization of a spectrometer for Spectral Domain Optical Coherence Tomography

Autores
Hosseiny, H; Rosa, CC;

Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
There are several factors such as the chosen optical source, central wavelength, spectral bandwidth, spectrometer optical components and the detector specifications that affect the overall performance of a spectral domain optical coherence tomography (SD-OCT) imaging system. Among these factors a good design and implementation of the spectrometer is of paramount importance as it directly affects the system resolution, sensitivity fall-off, maximum imaging depth, SNR and in general the system performance. This study demonstrates the design steps and some considerations during the design of a spectrometer. The imaging performance of this design is assessed. The obtained experimental results prove an improvement of the overall performance of the common path SD-OCT imaging system and agree with the expected outcome from the design stage.

2014

Teaching Optics with the centennial universal lantern

Autores
Joao Carvalhal, MJ; Monteiro, M; Marques, MB;

Publicação
12TH EDUCATION AND TRAINING IN OPTICS AND PHOTONICS CONFERENCE

Abstract
A projection apparatus was bought in 1909 by the Physics Cabinet of the Polytechnic Academy (predecessor to the University of Porto's Faculty of Science) in order to present various physics experiments, mostly in the realm of Optics, to a large student audience. A stout and impressive mahogany and brass piece, with a voltaic arc lighting system, it was manufactured by the firm E. Leybold's Nachfolger, based in Chemnitz (Germany), already with a worldwide reputation as a supplier of teaching instruments and equipment to superior schools and universities. It was sold along with an extensive set of accessories, allowing for demonstrations in geometrical optics, spectrum analysis, interferometry, diffraction, polarization and double refraction. Two extra attachments, one for projecting microscopic objects, and the other for the projection of gypsum preparations in polarized light, added to the versatility of this lantern, appropriately dubbed of universal use. Both apparatus and accessories are presently to be found in the collection of the Museum of Science of our University. On studying them, we have come to the conclusion that many classical experiments in Optics may be displayed, without great effort and in an attractive manner. The adaptation to present day usage takes no more than the replacement of the lantern's voltaic arc by a suitable and safer light source. It so happens that a hundred-year old projection apparatus, fitted with a set of purposely designed add-ons, becomes so effective as its modern counterparts.

  • 109
  • 237