Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Tópicos
de interesse
Detalhes

Detalhes

  • Nome

    João Pedro Mendes
  • Cargo

    Investigador Auxiliar
  • Desde

    19 outubro 2016
  • Nacionalidade

    Portugal
  • Centro

    Fotónica Aplicada
  • Contactos

    +351220402301
    joao.p.mendes@inesctec.pt
008
Publicações

2026

Towards Haemoglobin Detection in Finger-Prick Sampling via Low-Cost Disposable Sensor Chips Based on eMIPs on Plasmonic Optical Fiber Probes

Autores
Pitruzzella, R; Cicatiello, D; Marzano, C; Passeggio, F; Gentile, L; Ribeiro, JA; Mendes, JP; Coelho, LCC; Portella, G; Capellupo, MC; Casale, M; Zeni, L; Jorge, PAS; Cennamo, N;

Publicação
NANOMATERIALS

Abstract
Haemoglobin (Hb) concentration is a key biomarker for several diseases. Traditional laboratory methods often have limitations due to their time-consuming nature, the need for skilled personnel, or the use of high-cost instrumentation. This work presents a sensing strategy for developing new point-of-care tests (POCTs) for Hb detection via a proof of concept. The proposed sensing approach is implemented using plasmonic plastic optical fiber (POF) sensor chips that integrate an electropolymerized molecularly imprinted polymer (eMIP) film on the plasmonic surface for Hb-selective detection. The developed sensor system demonstrates an ultra-low detection limit of 80 fM in buffer, about five orders of magnitude lower than that of other comparable Hb sensors. Selectivity tests against common interfering proteins, such as bovine serum albumin (BSA) and immunoglobulin G (IgG), confirmed high specificity towards the target analyte. Moreover, the sensor's performance was tested using a whole-blood sample, yielding results consistent with those of standard haematology analysis. The proposed sensor system, based on simple equipment, provides a quick (about 10 min) and cost-effective (about 10 euros per chip) label-free diagnostic tool for POCTs in real-world scenarios, such as finger-prick sampling, offering a less invasive alternative to traditional laboratory methods, towards devices useful for Internet of Medical Things (IoMT).

2026

Fast Hydrogen Detection via Optical Fibers Coated with Metal Hydride Thin Films

Autores
Santos, AD; Almeida, MAS; Mendes, JP; Almeida, JMMMd; Coelho, LCC;

Publicação
Sensors

Abstract
Detection of leaks in hydrogen (H2) infrastructure is required on a large scale to enable a safe widespread use of this clean energy source. Sensing solutions must be low-cost, use scalable fabrication methods and allow multiplexed detection while providing reliable safety alarms as fast as possible. Optical methods can make this possible while avoiding the risk of ignition due to electronics at the point of detection. Metal hydride-based micro-mirror configurations benefit from a simple interrogation scheme, as long as the sensitive element can produce a large optical response. Magnesium thin films undergo a drastic variation of properties when hydrogenated, making them suitable for this application. In this work, a micro-mirror device using single-mode fibers capable of detecting the presence of H2 with a loading t10 and t90 of 1.2 and 3.0 s, respectively, is demonstrated. A complete interrogation unit was developed, presenting a solution suited for widespread deployment using industry-standard optical components and equipment.

2025

Anisotropic plasmonic nano emitters to excite surface plasmon polaritons on thin film-coated tapered optical fibers

Autores
dos Santos, PSS; Mendes, JP; Pastoriza Santos, I; de Almeida, JMMM; Coelho, LCC;

Publicação
29TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS

Abstract
The phase-matching conditions for exciting surface plasmon resonances (SPR) in plasmonic films are typically satisfied via prism, optical fibers or grating-assisted coupling. We recently showed that plasmonic nanospheres can act as local emitters, exciting SPR waves on thin films-termed nanoparticle-induced SPR (NPI-SPR). This structure holds promise for sensing, but the effects of optical fiber geometry and nanoparticle anisotropy on the response were unexplored. This study examines these factors, showing that an etched multimode fiber with a 200 mu m core diameter, taper ratio of 4, and etching angle of 20 degrees optimizes interaction with plasmonic nanoparticles. Tuning the nanoparticle aspect ratio from 1 to 3 shifts the NPI-SPR band from 780 to 1580 nm, with excitation highly dependent on the incident light angle. Notably, for light incident parallel to the film plane, a refractive index sensitivity exceeding 1000 nm/RIU is achieved. This efficient light emission combines the field locality enhancements of plasmonic nanoparticle-on-film structures with the emission efficiency of plasmonic nanoantennas, advancing plasmonic optical fiber chemical and biosensors.

2025

Low-Cost Versatile Optical Fiber Sensor for Structural Health Monitoring of Reinforced Concrete Structures

Autores
da Silva, PM; Mendes, JP; Coelho, LCC; de Almeida, JMMM;

Publicação
29TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS

Abstract
Reinforced concrete structures form the backbone of civil infrastructure due to their durability, longevity, affordability, and availability. However, aging concrete poses challenges, with decay often beginning internally and becoming visible only at advanced stages, leading to costly repairs, restricted functionality, and safety risks. To address these challenges, sensors are crucial for enhancing infrastructure resilience and optimizing repairs. This study employs multimode optical fibers to monitor concrete curing, water ingress, relative humidity (RH), cement paste carbonation, and rebar corrosion. Four sensors monitor changes in reflection at the fiber tip of a 600 mu m multimode fiber (MMF) using LEDs and photodiodes, connected via a fiber bundle containing two 200 mu m MMF. Variations in the refractive index around the fiber tip are used to monitor water throughout the concrete lifecycle, including curing, RH changes and water intrusion. Colorimetric changes in a cement paste layer and an iron-thin film are used to monitor carbonation and corrosion. The curing sensor is temperature-independent and correlates strongly with cumulative heat release from cement hydration (R=0.95). The RH sensor monitors up to and beyond 100% RH, detecting water intrusion. The corrosion sensor detects early corrosion stages and distinguishes between reflection losses from corrosion and mechanical changes. The layer of cement paste for carbonation monitoring increases reflected intensity by 17% due to carbonation, with 63% of the increase occurring in 80 minutes in a 3% CO2 atmosphere. The broad monitoring scope and low implementation cost make this sensor a unique option among commercially available solutions for structural health monitoring of reinforced concrete.

2025

Optical Fiber Sensor for Glyphosate Detection Combining the Functionality of Gold and Plasmonic Properties of Silver Thin Films

Autores
Mendes, JP; dos Santosa, PSS; de Almeida, JMMM; Coelho, LCC;

Publicação
29TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS

Abstract
This study investigates the fabrication of plasmonic optical fiber sensors for glyphosate detection, employing silver thin film coatings deposited via the Tollens' reaction and further enhanced with protective gold plating. Silver films were produced through electroless deposition, forming rough plasmonic surfaces with localized hotspots that amplify the electromagnetic field. Surface roughness effects on the creation of hotspots were first evaluated numerically using the finite element method (FEM) and later experimentally assessed the impact on optical response. Furthermore, to address the inherent susceptibility of silver to oxidation and corrosion, a gold plating was applied using the Kirkendall effect, selectively replacing surface silver atoms with gold. This approach significantly improved the chemical stability of the sensors while preserving their plasmonic properties. This configuration was applied in developing a biosensor, using aptamers, for detecting glyphosate in concentrations ranging from 10(-1) to 10(4) mu g/L. The results demonstrated a sensitivity of 25.08 +/- 0.22 nm/(mu g/L) and a limit of detection (LOD) of 0.04 mu g/L, nearly ten times lower than the European Union's safety limit for glyphosate. Experimental results highlight the potential of this fabrication approach for developing sensitive, stable, and scalable plasmonic sensors tailored for environmental and agricultural monitoring applications.