2024
Authors
Robalinho, P; Rodrigues, A; Novais, S; Ribeiro, ABL; Silva, S; Frazao, O;
Publication
EOS ANNUAL MEETING, EOSAM 2024
Abstract
This work proposes a signal processing algorithm to analyse the optical signal from a Low Coherence Interferometric (LCI) system. The system uses a Mach-Zehnder (MZ) interferometer to interrogate a Fabry-Perot cavity, working as an optical sensor. This algorithm is based on the correlation and convolution operations, which allows the signal to be reconstructed based on itself, as well as, on the linearization of the signal phase, allowing the non-linearities of the actuator incorporated on the MZ interferometer to be compensated. The results show a noise reduction of 30 dB in the signal acquired. As a result, a reduction of 8.2 dB in the uncertainty of the measurement of the physical measurand is achieved. It is also demonstrated that the phase linearization made it possible to obtain a coefficient of determination (namely, R-squared) higher than 0.999.
2024
Authors
Soares, L; Novais, S; Ferreira, A; Frazao, O; Silva, S;
Publication
EOS ANNUAL MEETING, EOSAM 2024
Abstract
Optical fiber sensors were implemented to measure in-situ temperature variations in an oscillatory flow crystallizer operating in continuous. The sensors were fabricated by cleaved in the middle 8 mm-length fiber Bragg gratings, forming tips with a Bragg grating of 4 mm inscribed at the fiber ends. The geometry of the sensors fabricated, with a diameter of 125 mu m, allowed the temperature monitorization of the process flow, inside the crystallizer, at four different points: input, two intermediate points, and output. The results revealed that the proposed technology allows to perform an in-situ and in line temperature monitorization, during all the crystallization process, as an alternative to more expensive and complex technology.
2024
Authors
Robalinho, P; Rodrigues, AV; Novais, S; Ribeiro, AL; Silva, S; Frazao, O;
Publication
IEEE SENSORS JOURNAL
Abstract
The aim of this work is to introduce a novel digital signal processing method for data acquired using low coherence interferometry (LCI) with a 1-kHz actuator oscillation frequency. Convolution and correlation operations are employed as efficient filters, reducing computational complexity for multilayer filtering. An envelope filtering technique is developed to address discrepancies in peak signal determination caused by nonlinear actuator motion. Additionally, a phase linearization method is presented to normalize the peak position relative to the actuator signal. Experimental results demonstrate a significant signal-to-noise ratio (SNR) improvement of 50 dB. Long-term measurements reveal an 11-dB noise reduction for frequencies below 1 mHz. This research enables LCI implementation at sampling rates of at least 1 kHz and expands its applicability to extreme measurement conditions.
2024
Authors
Robalinho, P; Piaia, V; Soares, L; Novais, S; Ribeiro, AL; Silva, S; Frazao, O;
Publication
SENSORS
Abstract
This paper presents a new type of phase-shifted Fiber Bragg Grating (FBG): the sliced-FBG (SFBG). The fabrication process involves cutting a standard FBG inside its grating region. As a result, the last grating pitch is shorter than the others. The optical output signal consists of the overlap between the FBG reflection and the reflection at the fiber-cleaved tip. This new fiber optic device has been studied as a vibration sensor, allowing for the characterization of this sensor in the frequency range of 150 Hz to 70 kHz. How the phase shift in the FBG can be controlled by changing the length of the last pitch is also shown. This device can be used as a filter and a sensing element. As a sensing element, we will demonstrate its application as a vibration sensor that can be utilized in various applications, particularly in monitoring mechanical structures.
2024
Authors
Cunha, C; Monteiro, C; Vaz, A; Silva, S; Frazao, O; Novais, S;
Publication
OPTICAL SENSING AND DETECTION VIII
Abstract
This work provides a method that combines graphene oxide coating and self-image theory to improve the sensitivity of optical sensors. The sensor is designed specifically to measure the amount of glucose present quantitatively in aqueous solutions that replicate the range of glucose concentrations found in human saliva. COMSOL Multiphysics 6.0 was used to simulate the self-imaging phenomenon using a coreless silica fiber (CSF). For high-quality self-imaging, the second and fourth self-imaging points are usually preferred because of their higher coupling efficiency, which increases the sensor sensitivity. However, managing the fourth self-image is more difficult because it calls for a longer CSF length. As a result, the first and second self-image points were the focus of the simulation in this work. After the simulation, using the Layerby-Layer method, the sensor was constructed to a length that matched the second self-image point (29.12 mm) and coated with an 80 mu m/mL graphene oxide layer. When comparing uncoated and graphene oxide-covered sensors to measure glucose in liquids ranging from 25 to 200 mg/dL, one bilayer of polyethyleneimine/graphene demonstrated an eight-fold improvement in sensitivity. The final sensor, built on graphene oxide, showed stability with a low standard deviation of 0.6 pm/min. It also showed sensitivity at 10.403 +/- 0.004 pm/(mg/dL) with a limit of detection of 9.15 mg/dL.
2024
Authors
Soares, L; Perez-Herrera, RA; Novais, S; Ferreira, A; Silva, S; Frazao, O;
Publication
PHOTONICS
Abstract
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of (-3.00 +/- 0.24) pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.