2023
Authors
Dos Santos, PSS; Mendes, JP; Dias, B; Perez-Juste, J; De Almeida, JMMM; Pastoriza-Santos, I; Coelho, LCC;
Publication
SENSORS
Abstract
Biochemical-chemical sensing with plasmonic sensors is widely performed by tracking the responses of surface plasmonic resonance peaks to changes in the medium. Interestingly, consistent sensitivity and resolution improvements have been demonstrated for gold nanoparticles by analyzing other spectral features, such as spectral inflection points or peak curvatures. Nevertheless, such studies were only conducted on planar platforms and were restricted to gold nanoparticles. In this work, such methodologies are explored and expanded to plasmonic optical fibers. Thus, we study-experimentally and theoretically-the optical responses of optical fiber-doped gold or silver nanospheres and optical fibers coated with continuous gold or silver thin films. Both experimental and numerical results are analyzed with differentiation methods, using total variation regularization to effectively minimize noise amplification propagation. Consistent resolution improvements of up to 2.2x for both types of plasmonic fibers are found, demonstrating that deploying such analysis with any plasmonic optical fiber sensors can lead to sensing resolution improvements.
2023
Authors
Vasconcelos, H; Matias, A; Mendes, J; Araujo, J; Dias, B; Jorge, PAS; Saraiva, C; de Almeida, JMMM; Coelho, LCC;
Publication
TALANTA
Abstract
Hydrogen peroxide is usually added to products to delay the development of microorganisms mainly in milk, hence increasing its stability over time, however the side effects can become devastating to human health.A technique is presented consisting of detecting hydrogen peroxide as an adulterant in milk through a sensor where pretreatment of the sample is not necessary, using a single use membrane. The detection of hydrogen peroxide in fresh-raw, whole, semi-skimmed and skimmed milk was performed using a luminol chem-iluminescence reaction.For hydrogen peroxide water solutions, a linear response was attained from 1.0 x 10-4 to 9.0 x 10-3 %w/w and an LOD (limit of detection) of 3.0 x 10-5 %w/w was determined. An R-squared value of 0.97 and a relative standard deviation lower than 10%, were achieved.Hydrogen peroxide concentration as low as 1.0 x 10-3 %w/w was measured for fresh-raw, skim and whole milk and for semi-skimmed milk, as low as 2.0 x 10-3 %w/w.The methodology presented, as long as our knowledge, is original, rapid, ecological and inexpensive. In regard of the sensitivity obtained, the methodology has great possibility to be applied in the detection of hydrogen peroxide in several areas. It is envisaged monitoring of food quality, agriculture systems and environment pollution.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.