Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CAP

2020

Preface

Authors
Frazao, O; del Villar, I; Fabris, J; Gong, Y;

Publication
OPTICS AND LASER TECHNOLOGY

Abstract

2020

Tuning of Fiber Optic Surface Reflectivity through Graphene Oxide-Based Layer-by-Layer Film Coatings

Authors
Monteiro, CS; Raposo, M; Ribeiro, PA; Silva, SO; Frazao, O;

Publication
PHOTONICS

Abstract
The use of graphene oxide-based coatings on optical fibers are investigated, aiming to tune the reflectivity of optical fiber surfaces for use in precision sensing devices. Graphene oxide (GO) layers are successfully deposited onto optical fiber ends, either in cleaved or hollow microspheres, by mounting combined bilayers of polyethylenimine (PEI) and GO layers using the Layer-by-Layer (LbL) technique. The reflectivity of optical fibers coated with graphene oxide layers is investigated for the telecom region allowing to both monitor layer growth kinetics and cavity characterization. Tunable reflective surfaces are successfully attained in both cleaved optical fibers and hollow microsphere fiber-based sensors by simply coating them with PEI/GO layers through the LbL film technique.

2020

Curvature detection in a medical needle using a Fabry-Perot cavity as an intensity sensor

Authors
Novais, S; Silva, SO; Frazao, O;

Publication
MEASUREMENT

Abstract
The use of optical sensors inside the needle can improve targeting precision and can bring real-time information about the location of the needle tip if necessary, since a needle bends through insertion into the tissue. Therefore, the precise location of the needle tip is so important in percutaneous treatments. In the current experiment, a fiber sensor based on a Fabry-Perot (FP) cavity is described to measure the needle curvature. The sensor is fabricated by producing an air bubble between two sections of multimode fiber. The needle with the sensor therein was attached at one end and deformed by the application of movements. The sensor presents a sensitivity of -0.152 dB/m(-1) to the curvature measurements, with a resolution of 0.089 m(-1). The sensory structure revealed to be stable, obtaining a cross-sensitivity to be 0.03 m(-1)/degrees C.

2020

Curvature Sensor Based on a Long-Period Grating in a Fiber Ring Resonator Interrogated by an OTDR

Authors
Magalhaes, R; Silva, S; Frazao, O;

Publication
PHOTONIC SENSORS

Abstract
The proposed technique demonstrates a fiber ring resonator interrogated by an optical time domain reflectometer (OTDR), for intensity sensing. By using this methodology, a cavity round trip time of 2.85 mu s was obtained. For a proof of concept, a long-period grating was inserted in the resonant cavity operating as a curvature sensing device. A novel signal processing approach was outlined, regarding to the logarithmic behavior of the OTDR. Through analyzing the experimental results, an increase in the measured sensitivities was obtained by increasing applied bending. With curvatures performed from 1.8 m(-1) to 4.5 m(-1), the sensitivity values ranged from 2.94 dB center dot km(-1) to 5.15 dB center dot km(-1). In its turn, the sensitivities obtained presented a linear behavior when studied as a function of the applied curvature, following a slope of 0.86x10(-3) dB. The advantages of applying this technique were also discussed, demonstrating two similar fiber rings multiplexed in a series of configurations.

2020

Detection of the Crystallization Process of Paracetamol with a Multi-Mode Optical Fiber in a Reflective Configuration

Authors
Soares, L; Novais, S; Ferreira, A; Frazao, O; Silva, S;

Publication
SENSORS

Abstract
A configuration of a refractometer sensor is described with the aim of optically detecting the crystallization process of paracetamol. The developed sensing head is based on a conventional cleaved multi-mode fiber. The fiber tip sensor structure was submitted to contact with the liquid of interest (paracetamol fully dissolved in 40% v/v of ethanol/water) and the crystallization process of paracetamol, induced with continued exposure to air, was monitored in real time.

2020

Magnetostriction assessment with strain gauges and fiber bragg gratings

Authors
Linhares, CC; Santo, JE; Teixeira, RR; Coutinho, CP; Tavares, SMO; Pinto, M; Costa, JS; Mendes, H; Monteiro, CS; Rodrigues, AV; Frazão, O;

Publication
EAI Endorsed Transactions on Energy Web

Abstract
Power transformers have an imperative role in the future developments of the electrical grids. Treated as crucial assets for transportation and distribution of electrical energy, transformers are currently being studied regarding to the integration of technologies aiming to diagnose problems and monitoring data of electrical power grid. Furthermore, environmental noise pollution has gained importance, especially in active units of the power grid, located near consumers, such as transformers. Transformers noise can be classified according to its source: core, windings and cooling. This study addresses an experimental characterization of one of the main causes of transformers core noise-magnetostriction of electrical steel. An evaluation of magnetostriction properties of electrical steel, including resistive strain gauges and Fiber Bragg Gratings (FBGs) measurements with an Epstein frame, are presented and discussed. The magnetic flux density influence on hysteretic strain behavior of magnetostriction was evaluated, as well as the effect of a clamping load on core joints. Nowadays, optical interrogators for Bragg gratings have a high acquisition frequencies and wavelength sensitivity when compared to former optical interrogation systems, allowing to evaluate physical phenomena without electromagnetic interference and with equivalent resolution of conventional strain gauges. © 2019 Cassiano C. Linhares et al.

  • 38
  • 231