2021
Authors
Monteiro, CS; Raposo, M; Ribeiro, PA; Silva, SO; Frazao, O;
Publication
SENSORS
Abstract
A Fabry-Perot acoustic sensor based on a graphene oxide membrane was developed with the aim to achieve a faster and simpler fabrication procedure when compared to similar graphene-based acoustic sensors. In addition, the proposed sensor was fabricated using methods that reduce chemical hazards and environmental impacts. The developed sensor, with an optical cavity of around 246 mu m, showed a constant reflected signal amplitude of 6.8 +/- 0.1 dB for 100 nm wavelength range. The sensor attained a wideband operation range between 20 and 100 kHz, with a maximum signal-to-noise ratio (SNR) of 32.7 dB at 25 kHz. The stability and sensitivity to temperatures up to 90 degrees C was also studied. Moreover, the proposed sensor offers the possibility to be applied as a wideband microphone or to be applied in more complex systems for structural analysis or imaging.
2021
Authors
Gomes, AD; Bartelt, H; Frazao, O;
Publication
LASER & PHOTONICS REVIEWS
Abstract
The optical analog of the Vernier effect applied to fiber interferometers is a recent tool to enhance the sensitivity and resolution of optical fiber sensors. This effect relies on the overlap between the signals of two interferometers with slightly detuned interference frequencies. The Vernier envelope modulation generated at the output spectrum presents magnified sensing capabilities (i.e., magnified wavelength shift) compared to that of the individual sensing interferometers that constitute the system, leading to a new generation of highly sensitive fiber sensing devices. This review analyses the recent advances and developments of the optical Vernier effect from a fiber sensing point-of-view. Initially, the fundamentals of the effect are introduced, followed by an extensive review on the state-of-the-art, presenting all the different configurations and types of fiber sensing interferometers used to introduce the optical Vernier effect. This paper also includes an overview of the complex case of enhanced Vernier effect and the introduction of harmonics to the effect.
2021
Authors
Monteiro, CS; Rodrigues, AV; Viveiros, D; Linhares, C; Mendes, H; Silva, SO; Marques, PVS; Tavares, SMO; Frazao, O;
Publication
SENSORS
Abstract
Power transformers are central elements of power transmission systems and their deterioration can lead to system failures, causing major disruptions in service. Catastrophic failures can occur, posing major environmental hazards due to fires, explosions, or oil spillage. Early fault detection can be accomplished or estimated using electrical sensors or a chemical analysis of oil or gas samples. Conventional methods are incapable of real-time measurements with a low electrical noise due to time-consuming analyses or susceptibility to electromagnetic interference. Optical fiber sensors, passive elements that are immune to electromagnetic noise, are capable of structural monitoring by being enclosed in power transformers. In this work, optical fiber sensors embedded in 3D printed structures are studied for vibration monitoring. The fiber sensor is encapsulated between two pressboard spacers, simulating the conditions inside the power transformer, and characterized for vibrations with frequencies between 10 and 800 Hz, with a constant acceleration of 10 m/s(2). Thermal aging and electrical tests are also accomplished, aiming to study the oil compatibility of the 3D printed structure. The results reported in this work suggest that structural monitoring in power transformers can be achieved using optical fiber sensors, prospecting real-time monitoring.
2021
Authors
Soares, L; Cruz, P; Novais, S; Ferreira, A; Frazao, O; Silva, S;
Publication
IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE
Abstract
A refractometric sensor was applied to measure in real-time the concentration of Active Pharmaceutical Ingredients (APIs) in crystallization experiments. Paracetamol was used as a model system due to the extensive literature available for this API. The refractometric sensor was fabricated by a simple and inexpensive method that consisted in splicing a short section of a multimode fiber to a single mode fiber. The compact geometry of this sensor, with an external diameter of just $125\ \mu\mathrm{m}$, allowed it to measure the concentration of paracetamol, both in a stirred tank crystallizer operating in batch and in an oscillatory flow crystallizer operating continuously. The proposed technique shows the potential to monitor the concentration of APIs in crystallizers of different sizes and geometries as an alternative to more expensive and complex analysis equipment.
2021
Authors
Peixoto, R; Pires, JPS; Monteiro, CS; Raposo, M; Ribeiro, PA; Silva, SO; Frazao, O; Lopes, JMVP;
Publication
PHYSICAL REVIEW APPLIED
Abstract
We propose a fiber-based environmental sensor that exploits the reflection-phase-shift tunability provided by the use of layered coatings composed of dielectric slabs spaced by conducting membranes. A transfer-matrix study is done in a simplified theoretical model, for which an enhanced sensitivity of the reflection interference pattern to the output medium is demonstrated, in the typical refractive index range of liquid media. An experimental configuration using a cascaded Fabry-Perot microcavity coated by a graphene oxide/polyethylenimine (GO/PEI) multilayered structure is demonstrated. Its cost-effective chemical production method makes graphene oxide-based hybrid coatings excellent candidates for future real-life sensing devices.
2021
Authors
Marques J.; Novais S.; Silva S.; Frazao O.;
Publication
2021 Telecoms Conference, ConfTELE 2021
Abstract
Two distinct optical fibers for endoscope-based configurations are demonstrated and studied in this work. The fibers used for the experiment consist of: a conventional singlemode fiber (SMF 28e) and a hollow core photonic crystal fiber (HC-PCF) based on silica. Two studies that allowed the characterization of these fibers, according to their optical output power and when subjected to curvature, were carried out. The intensity power profile was also analysed in relation to the propagation distance, transversal displacement and incidence angle. After this study it can be concluded that the most suitable solution for the endoscope is the HC-PCF fiber working as a transmission probe. For the proof of concept of the fiber-based endoscope, a cleaved multimode fiber (MMF) tip was used as a reception probe and its reflection efficiency was also analysed.