2022
Authors
Cardoso, VHR; Caldas, P; Giraldi, MTR; Frazao, O; Costa, JCWA; Santos, JL;
Publication
SENSORS
Abstract
An optical strain gauge based on a balloon-like interferometer structure formed by a bent standard single-mode fiber combined with a 3D printer piece has been presented and demonstrated, which can be used to measure displacement. The interferometer has a simple and compact size, easy fabrication, low cost, and is repeatable. The sensor is based on the interference between the core and cladding modes. This is caused by the fiber's curvature because when light propagates through the curved balloon-shaped interferometer region, a portion of it will be released from the core limitation and coupled to the cladding. The balloon has an axial displacement as a result of how the artwork was constructed. The sensor head is sandwiched between two cantilevers such that when there is a displacement, the dimension associated with the micro bend is altered. The sensor response as a function of displacement can be determined using wavelength shift or intensity change interrogation techniques. Therefore, this optical strain gauge is a good option for applications where structure displacement needs to be examined. The sensor presents a sensitivity of 55.014 nm for displacement measurements ranging from 0 to 10 mm and a strain sensitivity of 500.13 pm/mu epsilon.
2022
Authors
Martins, RC; Barroso, TG; Jorge, P; Cunha, M; Santos, F;
Publication
COMPUTERS AND ELECTRONICS IN AGRICULTURE
Abstract
Analytical grade 'in vivo' plant metabolic quantification using spectroscopy is a key enabling technology for precision agriculture.Current methods such as PLS, ANN and LS-SVM are non-optimal for resolving spectral interference and matrix effects to provide similar results to the analytical chemistry laboratory. This research presents a new self-learning artificial intelligence (SL-AI) method based on the search of covariance modes. These isolate the different modes of interference present in spectral data, allowing the consistent quantification of constituents. A review of the state-of-the-art methods with the figures of merit mean absolute standard error percentage (MASEP) and Pearson correlation coefficient (R) is presented for comparison and discussion. 707 grapes were quantified for glucose, fructose, malic and tartaric acids in five wine-making and one table grape varieties, and used to benchmark the new method against the state-of-the-art methodologies: partial least squares, local partial least squares, artificial neural networks and least squares support vector machines. SL-AI provides consistent quantifications, whereas previous methods exhibit data-driven performance dependence. Pearson correlations of 0.93 to 0.99 and MASEP of 3.70% to 7.33% were obtained with the new methodology. Local partial least squares, the method with the best benchmarks from literature, achieved correlations of 0.81 to 0.94 and MASEP of 8.00% to 13.4%. The covariance mode isolates a particular interference, providing a direct relationship between spectral inference and constituent concentrations, consistent with the Beer-Lambert law. Such quantifies non-dominant absorbance constituents (e.g. sugars and acids), which is a significant step towards 'in vivo' plant physiology-based precision agriculture.
2022
Authors
Arcadio, F; Seggio, M; Del Prete, D; Buonanno, G; Mendes, J; Coelho, LCC; Jorge, PAS; Zeni, L; Bossi, AM; Cennamo, N;
Publication
NANOMATERIALS
Abstract
Plasmonic bio/chemical sensing based on optical fibers combined with molecularly imprinted nanoparticles (nanoMIPs), which are polymeric receptors prepared by a template-assisted synthesis, has been demonstrated as a powerful method to attain ultra-low detection limits, particularly when exploiting soft nanoMIPs, which are known to deform upon analyte binding. This work presents the development of a surface plasmon resonance (SPR) sensor in silica light-diffusing fibers (LDFs) functionalized with a specific nanoMIP receptor, entailed for the recognition of the protein human serum transferrin (HTR). Despite their great versatility, to date only SPR-LFDs functionalized with antibodies have been reported. Here, the innovative combination of an SPR-LFD platform and nanoMIPs led to the development of a sensor with an ultra-low limit of detection (LOD), equal to about 4 fM, and selective for its target analyte HTR. It is worth noting that the SPR-LDF-nanoMIP sensor was mounted within a specially designed 3D-printed holder yielding a measurement cell suitable for a rapid and reliable setup, and easy for the scaling up of the measurements. Moreover, the fabrication process to realize the SPR platform is minimal, requiring only a metal deposition step.
2022
Authors
Ferreira, MFS; Silva, NA; Guimarães, D; Martins, RC; Jorge, PAS;
Publication
U.Porto Journal of Engineering
Abstract
Laser-induced breakdown spectroscopy (LIBS) is a technique that leverages atomic emission towards element identification and quantification. While the potential of the technology is vast, it still struggles with obstacles such as the variability of the technique. In recent years, several methods have exploited modifications to the standard implementation to work around this problem, mostly focused on the laser side to increase the signal-to-noise ratio of the emission. In this paper, we explore the effect of pulse duration on the detected signal intensity using a tunable LIBS system that consists of a versatile fiber laser, capable of emitting square-shaped pulses with a duration ranging from 10 to 100 ns. Our results show that, by tuning the duration of the pulse, it is possible to increase the signal-to-noise ratio of relevant elemental emission lines, an effect that we relate with the computed plasma temperature and associated density for the ion species. Despite the limitations of the work due to the low-resolution and small range of the spectrometer used, the preliminary results pave an interesting path towards the design of controllable LIBS systems that can be tailored to increase the signal-to-noise ratio and thus be useful for the deployment of more sensitive instruments both for qualitative and quantitative purposes. © 2022, Universidade do Porto - Faculdade de Engenharia. All rights reserved.
2022
Authors
Silva N.A.; Capela D.; Ferreira M.; Gonçalves F.; Lima A.; Guimarães D.; Jorge P.A.S.;
Publication
Results in Optics
Abstract
One of the caveats of laser-induced breakdown spectroscopy technique is the performance for quantification purposes, in particular when the matrix of the sample is complex or the problem spans over a wide range of concentrations. These two questions are key issues for geology applications including ore grading in mining operations and typically lead to sub-optimal results. In this work, we present the implementation of a class of clustered regression calibration algorithms, that previously search the sample space looking for similar samples before employing a linear calibration model that is trained for that cluster. For a case study involving lithium quantification in three distinct exploration drills, the obtained results demonstrate that building local models can improve the performance of standard linear models in particular in the lower concentration region. Furthermore, we show that the models generalize well for unseen data of exploration drills on distinct rock veins, which can motivate not only further research on this class of methods but also technological applications for similar mining environments.
2022
Authors
Mendes, JP; Coelho, LCC; Jorge, PAS; Pereira, CM;
Publication
BIOSENSORS-BASEL
Abstract
A new sensing platform based on long-period fiber gratings (LPFGs) for direct, fast, and selective detection of human immunoglobulin G (IgG; Mw = 150 KDa) was developed and characterized. The transducer's high selectivity is based on the specific interaction of a molecularly imprinted polymer (MIPs) design for IgG detection. The sensing scheme is based on differential refractometric measurements, including a correction system based on a non-imprinted polymer (NIP)-coated LPFG, allowing reliable and more sensitive measurements, improving the rejection of false positives in around 30%. The molecular imprinted binding sites were performed on the surface of a LPFG with a sensitivity of about 130 nm/RIU and a FOM of 16 RIU-1. The low-cost and easy to build device was tested in a working range from 1 to 100 nmol/L, revealing a limit of detection (LOD) and a sensitivity of 0.25 nmol/L (0.037 mu g/mL) and 0.057 nm.L/nmol, respectively. The sensor also successfully differentiates the target analyte from the other abundant elements that are present in the human blood plasma.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.