2011
Authors
Frazao, O; Silva, SO; Viegas, J; Ferreira, LA; Araujo, FM; Santos, JL;
Publication
APPLIED OPTICS
Abstract
This paper presents an overview of optical fiber sensors based on multimode interference with a focus on refractometric applications. A specific configuration is presented to measure the refractive index of the surrounding liquid based on the Fresnel reflection in the fiber tip, combined with a simple interrogation technique that uses two fiber Bragg gratings as discrete optical sources, with the measurand information encoded in the relative intensity variation of the reflected signals. A resolution of 1.75 x 10(-3) RIU is achieved. (C) 2011 Optical Society of America
2011
Authors
Santos, JL; Ferreira, LA; Araujo, FM;
Publication
Fiber Bragg Grating Sensors: Recent Advancements, Industrial Applications and Market Exploitation
Abstract
Fiber Bragg Gratings are structures with remarkable characteristics that have induced new qualitative developments in the broad field of optical fiber technology, most notably in optical communications and in optical sensing. When these devices are applied for sensing, the underlying concept is the modulation of the grating Bragg wavelength by the measured and, therefore, a central issue is the sensitive and accurate conversion of the resonant wavelength into a proportional electrical signal with the adequate format for further processing. This topic is broadly known as Fiber Bragg Grating interrogation and is the subject of the present chapter. It is organized in two parts: in the first one, the techniques developed by the scientific community looking for this functionality are reviewed, with emphasis on the identification of general conceptual classes where they fit; in the second part, illustrative and state-of-the-art commercial Fiber Bragg Grating interrogation systems are described.
2011
Authors
Rego, G; Caldas, P; Ivanov, O; Santos, JL;
Publication
OPTICS COMMUNICATIONS
Abstract
A long-period grating written in the SMF-28 fibre was heat treated at 1000 degrees C for 15 days. The spectrum of the grating shifted to longer wavelengths and the resonances depth decreased as a result of structural relaxation. The background loss increased considerably for times longer than 200 h, and this loss is caused by devitrification of the fibre.
2011
Authors
Erdmanis, M; Viegas, D; Hautakorpi, M; Novotny, S; Santos, JL; Ludvigsen, H;
Publication
OPTICS EXPRESS
Abstract
We present and numerically characterize a surface-plasmon-resonance sensor based on an H-shaped optical fiber. In our design, the two U-shaped grooves of the H-fiber are first coated with a thin gold layer and then covered by a uniform titanium dioxide layer to facilitate spectral tuning of the device. A finite element method analysis of the sensor indicates that a refractive-index resolution of up to 5.10(3) nm/RIU can be obtained. (C) 2011 Optical Society of America
2011
Authors
Santos, JL; Pandita, D; Rodrigues, J; Pego, AP; Granja, PL; Tomas, H;
Publication
CURRENT GENE THERAPY
Abstract
Mesenchymal stem cells (MSCs) can be isolated from several tissues in the body, have the ability to self-renewal, show immune suppressive properties and are multipotent, being able to generate various cell types. At present, due to their intrinsic characteristics, MSCs are considered very promising in the area of tissue engineering and regenerative medicine. In this context, genetic modification can be a powerful tool to control the behavior and fate of these cells and be used in the design of new cellular therapies. Viral systems are very effective in the introduction of exogenous genes inside MSCs. However, the risks associated with their use are leading to an increasing search for non-viral approaches to attain the same purpose, even if MSCs have been shown to be more difficult to transfect in this way. In the past few years, progress was made in the development of chemical and physical methods for non-viral gene delivery. Herein, an overview of the application of those methods specifically to MSCs is given and their use in tissue engineering and regenerative medicine therapeutic strategies highlighted using the example of bone tissue. Key issues and future directions in non-viral gene delivery to MSCs are also critically addressed.
2011
Authors
Silva, S; Santos, JL; Malcata, FX; Kobelke, J; Schuster, K; Frazao, O;
Publication
OPTICS LETTERS
Abstract
A large-core air-clad photonic crystal fiber-based sensing structure is described, which is sensitive to refractive index. The sensing head is based on multimodal interference, and relies on a single-mode/large-core air-clad photonic crystal fiber (PCF)/single-mode fiber configuration. Using two distinct large-core air-clad PCF geometries-one for refractive index measurement and the other for temperature compensation, it was possible to implement a sensing head sensitive to refractive index changes in water as induced by temperature variations. The results indicated the high sensitivity of this sensing head to refractive index variations of water, and a resolution of 3: 4 x 10(-5) refractive index units could be achieved. (C) 2011 Optical Society of America
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.