Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CAP

2013

On the improvement of strain measurements with FBG sensors embedded in unidirectional composites

Authors
Pereira, G; Frias, C; Faria, H; Frazao, O; Marques, AT;

Publication
POLYMER TESTING

Abstract
Optical fibre Bragg grating (FBG) sensors are now quite established and widely used in strain measurements of composites. However, insufficient understanding of the limitations of the embedment and measuring techniques often lead to inaccurate and inconclusive results. In this study, a novel method to improve the reliability and accuracy of the strain measurements on unidirectional composites using embedded FBG sensors was successfully developed. Using a carbon/epoxy prepreg system, test specimens were manufactured with longitudinally embedded FBG sensors. The combined behaviour of the sensors and the host material was characterized and a calibration rule (correction factor) was determined for the chosen material. The consistency of the results with both theoretical and empirical assumptions suggests that the proposed method is applicable to a wide range of FBG sensors and host materials.

2013

Optical inclinometer based on phase-shifted Bragg grating in a taper configuration

Authors
Moura, JPP; Silva, SO; Becker, M; Rothardt, M; Bartelt, H; Frazao, O;

Publication
FIFTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS

Abstract
A simple optical inclinometer based on phase-shifted Bragg grating in a taper configuration is proposed. The phase-shifted FBG was fabricated using a DUV femtosecond laser technique in the taper region. The sensing head was characterized for different angle curvatures and also to strain. The angle and strain sensitivities of the inclinometer are 13.15 pm/degree and 8.96 pm/mu epsilon.

2013

High visibility phase-sensitive optical time domain reflectometer for distributed sensing of ultrasonic waves

Authors
Martins, HF; Martin Lopez, S; Corredera, P; Filograno, ML; Frazao, O; Gonzalez Herraez, M;

Publication
FIFTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS

Abstract
In structural health monitoring, the propagation of ultrasonic waves along a structure can reveal interesting data relevant to the integrity of the whole structure. The availability of a system for distributed sensing of ultrasonic waves could, in some cases (e.g. pipelines) provide extremely valuable information to civil engineers. Phase-sensitive optical time domain reflectometry (phi OTDR) is a simple and effective tool allowing the distributed monitoring of vibrations along single-mode fibers. Up to now, phi OTDRs have been used mostly for the measurement of sub-kHz vibrations. In this work, the authors present an experimental characterization of a high-visibility phi OTDR and its performance when used for ultrasonic vibration measurements. The sensor was able to measure vibrations of up to 39.5 kHz with a resolution of 5 m over a range which could go up to 1.25 km. This is the first time to our knowledge that a phi OTDR is demonstrated for distributed measurement of ultrasonic waves.

2013

Temperature-independent torsion sensor based on "figure-of-eight" fiber loop mirror

Authors
Silva, RM; Ribeiro, ABL; Frazao, O;

Publication
Photonic Sensors

Abstract
An interrogation sensor system combining the "figure-of-eight" fiber loop mirror using a single directional 3×3 fiber optic coupler was proposed. One fiber loop mirror was formed by inserting a length of high birefringent optical fiber at the input ports of the 3×3 coupler. Splicing the output ports of the 3×3 coupler between them created the other fiber loop mirror. The introduction of this second loop gave rise to two polarization states of light with the same frequency but different optical phase. The mechanical torsion sensing head was located at the second loop and was exhibited an average modulus torsion sensitivity of 7.9×10-4 degree/dB. The performance of the sensor was not affected by environmental temperature variations. © 2012 The Author(s).

2013

Coherent Noise Reduction in High Visibility Phase-Sensitive Optical Time Domain Reflectometer for Distributed Sensing of Ultrasonic Waves

Authors
Martins, HF; Martin Lopez, S; Corredera, P; Filograno, ML; Frazao, O; Gonzalez Herraez, M;

Publication
JOURNAL OF LIGHTWAVE TECHNOLOGY

Abstract
Phase-sensitive optical time domain reflectometry (phi OTDR) is a simple and effective tool allowing the distributed monitoring of vibrations along single-mode fibers. Up to now, phi OTDRs have been used mostly for the measurement of sub-kHz vibrations, normally in the context of intrusion sensing. In this paper, the authors present an experimental and theoretical description of a high-visibility phi OTDR and its performance when used for ultrasonic vibration measurements. The use of a semiconductor optical amplifier in the setup allows to suppress coherent noise and also to improve the spectral response of the pump pulses. These two advantages greatly decrease the detected intra-band noise thus allowing frequency measurements in the limits set by the time of flight of the light pulses while maintaining the simplicity of the scheme, as no post-processing, extremely high coherence lasers or coherent detection methods are required. The sensor was able to measure vibrations of up to 39.5 kHz with a resolution of 5 m over a range which could go up to 1.25 km. This is the first time to our knowledge that a fully distributed measurement of ultrasonic waves was achieved. The statistical behavior of the system was also described theoretically and characterized experimentally.

2013

Study of strain-transfer of FBG sensors embedded in unidirectional composites

Authors
Pereira, G; Frias, C; Faria, H; Frazao, O; Marques, AT;

Publication
POLYMER TESTING

Abstract
Optical fibre Bragg grating (FBG) sensors are now quite established and widely used in strain measurements in composites. However, insufficient understanding of the limitations of the embedment and measuring techniques often leads to inaccurate results. This work is a continuation of a novel method to improve the reliability and accuracy of the strain measurements on unidirectional composites using embedded FBG sensors [1]. A new combination of the pair host material/sensor was studied and characterized. Test specimens were manufactured with longitudinally embedded FBG sensors, using a glass/epoxy prepreg system, in order to compare with a carbon/epoxy prepreg system. The combined behaviour of the sensors and the host material was characterized and a procedure to obtain a more accurate strain was defined for this new chosen material.

  • 120
  • 236