Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

2014

Declarative Programming and Knowledge Management - Declarative Programming Days, KDPD 2013, Unifying INAP, WFLP, and WLP, Kiel, Germany, September 11-13, 2013, Revised Selected Papers

Autores
Hanus, M; Rocha, R;

Publicação
KDPD

Abstract

2014

Hexapod Robot Energy Consumption Dependence on Body Elevation and Step Height

Autores
Luneckas, M; Luneckas, T; Udris, D; Ferreira, NMF;

Publicação
ELEKTRONIKA IR ELEKTROTECHNIKA

Abstract
Walking robots are well known for being able to walk over rough terrain and adapt to various environments. Hexapod robots are chosen because of their better stability and higher number of different gaits. However, having to hold the whole weight of the body and a large number of actuators makes all walking robots less energetically efficient than wheeled machines. Special methods for energy consumption optimization must be found. In this paper, hexapod robot energy consumption dependence on body elevation and step height is presented. Three main hexapod gaits are used: tripod, tetrapod and wave. Experimental results show that energy consumption does not depend on body elevation or gait. Although, higher steps increases the power consumption. Therefore, when walking over even terrain, lower step heights along with higher body elevation must be selected for tripod or tetrapod gait in order to surpass ground irregularities but still maintain maximum energetic efficiency.

2014

MPL—A Mission Planning Language for Autonomous Surface Vehicles

Autores
Cabral, HMP; Alves, JC; Cruz, NA; Valente, JF; Lopes, DM;

Publicação
Robotic Sailing 2013

Abstract

2014

An approach to implement data fusion techniques in wireless sensor networks using genetic machine learning algorithms

Autores
Pinto, AR; Montez, C; Araujo, G; Vasques, F; Portugal, P;

Publicação
INFORMATION FUSION

Abstract
Wireless Sensor Networks (WSNs) can be used to monitor hazardous and inaccessible areas. In these situations, the power supply (e.g. battery) of each node cannot be easily replaced. One solution to deal with the limited capacity of current power supplies is to deploy a large number of sensor nodes, since the lifetime and dependability of the network will increase through cooperation among nodes. Applications on WSN may also have other concerns, such as meeting temporal deadlines on message transmissions and maximizing the quality of information. Data fusion is a well-known technique that can be useful for the enhancement of data quality and for the maximization of WSN lifetime. In this paper, we propose an approach that allows the implementation of parallel data fusion techniques in IEEE 802.15.4 networks. One of the main advantages of the proposed approach is that it enables a trade-off between different user-defined metrics through the use of a genetic machine learning algorithm. Simulations and field experiments performed in different communication scenarios highlight significant improvements when compared with, for instance, the Gur Game approach or the implementation of conventional periodic communication techniques over IEEE 802.15.4 networks.

2014

Assessment of the pulse wave variability for a new non-invasive device

Autores
Almeida, VG; Pereira, HC; Pereira, T; Ferreira, LR; Correia, C; Cardoso, J;

Publicação
IFMBE Proceedings

Abstract
The main motivation of this work was to provide a valid contribution for the assessment of the cardiovascular condition by the analysis of several Arterial Pressure Waveform (APW) parameters collected by a new non-invasive device. Three sets of recordings for the carotid pressure waveform at left and right carotid arteries were performed, under standardized conditions, in 20 volunteers by three trained operators. The mean of the inter-operator differences were higher for the right artery, comparatively to the left artery. In this case, an Augmentation Index (AIx) value of -2.31 ± 7.29 % and a Systolic Wave Transit Time (SWTT) value of -12.94 ± 31.46 ms were observed, which are higher than the left measurements, 0.94 ± 7.52 % and -2.96 ± 22.67 ms, respectively. Intra-operator differences were calculated for each of the three sets of measurements and showed good reproducibility. The pulse-by-pulse variability analysis gives very good markers for the Left Ventricular Ejection Time (LVET), Dicrotic Wave Amplitude (DWA), Reflection Wave Amplitude (RWA), Coefficient of Variation (CV) < 10 %, and satisfactory values for the AIx (CV< 30 %). The SWTT and Reflected Wave Transit Time (RWTT) also presented satisfactory results (10 %

2014

DNA-Aptamer optical biosensors based on a LPG-SPR optical fiber platform for point-of care diagnostic

Autores
Coelho, L; Queiros, RB; Santos, JL; Martins, MCL; Viegas, D; Jorge, PAS;

Publicação
PLASMONICS IN BIOLOGY AND MEDICINE XI

Abstract
Surface Plasmon Resonance (SPR) is the base for some of the most sensitive label free optical fiber biosensors. However, most solutions presented to date require the use of fragile fiber optic structure such as adiabatic tapers or side polished fibers. On the other hand, long-period fiber gratings (LPG) present themselves as an interesting solution to attain an evanescent wave refractive index sensor platform while preserving the optical fiber integrity. The combination of these two approaches constitute a powerful platform that can potentially reach the highest sensitivities as it was recently demonstrated by detailed theoretical study [1, 2]. In this work, a LPG-SPR platform is explored in different configurations (metal coating between two LPG - symmetric and asymmetric) operating in the telecom band (around 1550 nm). For this purpose LPGs with period of 396 mu m are combined with tailor made metallic thin films. In particular, the sensing regions were coated with 2 nm of chromium to improve the adhesion to the fiber and 16 nm of gold followed by a 100 nm thick layer of TiO2 dielectric material strategically chosen to attain plasmon resonance in the desired wavelength range. The obtained refractometric platforms were then validated as a biosensor. For this purpose the detection of thrombin using an aptamer based probe was used as a model system for protein detection. The surface of the sensing fibers were cleaned with isopropanol and dried with N-2 and then the aminated thrombin aptamer (5'-[NH2]-GGTTGGTGTGGTTGG-3') was immobilized by physisorption using Poly-L-Lysine (PLL) as cationic polymer. Preliminary results indicate the viability of the LPFG-SPR-APTAMER as a flexible platforms point of care diagnostic biosensors.

  • 3118
  • 4542