Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

2021

X-ray Fluorescence and Laser-Induced Breakdown Spectroscopy Analysis of Li-Rich Minerals in Veins from Argemela Tin Mine, Central Portugal

Autores
Ribeiro, R; Capela, D; Ferreira, M; Martins, R; Jorge, P; Guimaraes, D; Lima, A;

Publicação
MINERALS

Abstract
In this work, X-ray fluorescence (XRF) and Laser-induced breakdown spectroscopy (LIBS) analyses were applied to samples of quartz, montebrasite, and turquoise hydrothermal veins in the Argemela Tin Mine (Central Portugal). Montebrasite (LiAl(PO4)(OH,F)) is potentially the main ore mineral; with its alteration, lithium (Li) can disseminate into other minerals. A hand sample was cut and analyzed by XRF and LIBS for several elements of interest including Cu, P, Al, Si, and Li. Although XRF cannot measure Li, results from its analysis are effective for distinguishing turquoise from montebrasite. LIBS analysis complemented this study, making it possible to conclude that turquoise does not contain any significant Li in its structure. The difference in spot size between the techniques (5 mm vs. 300 mu m for XRF and LIBS, respectively) resulted in a poorer performance by XRF in accurately identifying mixed minerals. A thin section was petrographically characterized and mapped using LIBS. The mapping results demonstrate the possibility of the successful identification of minerals and their alterations on a thin section. The results of XRF analysis and LIBS mapping in petrographic sections demonstrate the efficacy of these methods as tools for element and mineral identification, which can be important in exploration and mining phases, complementing more traditional techniques.

2021

Optimal Sizing of a Hybrid Energy System Based on Renewable Energy Using Evolutionary Optimization Algorithms

Autores
Amoura, Y; Ferreira, AP; Lima, J; Pereira, AI;

Publicação
OPTIMIZATION, LEARNING ALGORITHMS AND APPLICATIONS, OL2A 2021

Abstract
The current trend in energy sustainability and the energy growing demand have given emergence to distributed hybrid energy systems based on renewable energy sources. This study proposes a strategy for the optimal sizing of an autonomous hybrid energy system integrating a photovoltaic park, a wind energy conversion, a diesel group, and a storage system. The problem is formulated as a uni-objective function subjected to economical and technical constraints, combined with evolutionary approaches mainly particle swarm optimization algorithm and genetic algorithm to determine the number of installation elements for a reduced system cost. The computational results have revealed an optimal configuration for the hybrid energy system.

2021

Data stream analysis: Foundations, major tasks and tools

Autores
Bahri, M; Bifet, A; Gama, J; Gomes, HM; Maniu, S;

Publicação
WILEY INTERDISCIPLINARY REVIEWS-DATA MINING AND KNOWLEDGE DISCOVERY

Abstract
The significant growth of interconnected Internet-of-Things (IoT) devices, the use of social networks, along with the evolution of technology in different domains, lead to a rise in the volume of data generated continuously from multiple systems. Valuable information can be derived from these evolving data streams by applying machine learning. In practice, several critical issues emerge when extracting useful knowledge from these potentially infinite data, mainly because of their evolving nature and high arrival rate which implies an inability to store them entirely. In this work, we provide a comprehensive survey that discusses the research constraints and the current state-of-the-art in this vibrant framework. Moreover, we present an updated overview of the latest contributions proposed in different stream mining tasks, particularly classification, regression, clustering, and frequent patterns. This article is categorized under: Fundamental Concepts of Data and Knowledge > Key Design Issues in Data Mining Fundamental Concepts of Data and Knowledge > Motivation and Emergence of Data Mining

2021

Clustering Algorithm to Measure Student Assessment Accuracy: A Double Study

Autores
Sobral, SR; de Oliveira, CF;

Publicação
BIG DATA AND COGNITIVE COMPUTING

Abstract
Self-assessment is one of the strategies used in active teaching to engage students in the entire learning process, in the form of self-regulated academic learning. This study aims to assess the possibility of including self-evaluation in the student's final grade, not just as a self-assessment that allows students to predict the grade obtained but also as something to weigh on the final grade. Two different curricular units are used, both from the first year of graduation, one from the international relations course (N = 29) and the other from the computer science and computer engineering courses (N = 50). Students were asked to self-assess at each of the two evaluation moments of each unit, after submitting their work/test and after knowing the correct answers. This study uses statistical analysis as well as a clustering algorithm (K-means) on the data to try to gain deeper knowledge and visual insights into the data and the patterns among them. It was verified that there are no differences between the obtained grade and the thought grade by gender and age variables, but a direct correlation was found between the thought grade averages and the grade level. The difference is less accentuated at the second moment of evaluation-which suggests that an improvement in the self-assessment skill occurs from the first to the second evaluation moment.

2021

Intensity-modulated refractometer based on mode-mismatch in surface waveguides inscribed by femtosecond laser direct writing

Autores
Amorim, VA; Viveiros, D; Maia, JM; Marques, PVS;

Publicação
OPTICS AND LASER TECHNOLOGY

Abstract
Optical waveguides were fabricated at the surface of Eagle2000 glass substrates, using femtosecond laser direct writing and wet etching, and their potential as intensity-modulated refractometers was assessed. Through the analysis of their broadband spectral response to different refractive index oils, we observed that mode mismatch is present when the guided mode reaches the surface of the substrate and interacts with the external medium, thus enabling the use of such optical waveguides in refractive index sensing. Refractive indices equal to or greater than that of the substrate also induced a coupling mechanism that was shown not to be suitable in these devices. The device's wavelength of operation was found to be tunable by controlling the distance between the surface and the center of the optical waveguide. However, the sensitivity was seen to diminish by increasing the latter, being nonexistent for distances greater than 5.5 mu m. In this study, the maximum sensitivity values were found for a surface to core center distance between 1 and 2 mu m, in the biological range, and 2.5 to 3 mu m, for a refractive index nearing that of the substrate. Accordingly, maximum sensitivities of approximate to 25 dB/RIU and approximate to 1200 dB/RIU were found between 1.300 < n(D)(25)degrees(C) < 1.400 and 1.490 < n(D)(25)degrees(C) < 1.500, respectively.

2021

A New Coupling Method for Accurate Measurement of Pedicle Screw Electrical Properties for Surgical Procedures

Autores
Fonseca, P; Goethel, MF; Sebastiao, R; Sousa, MV; Vilas Boas, JP; Correia, MV; Gutierres, M;

Publicação
APPLIED SCIENCES-BASEL

Abstract
The objective of this study is to present a new coupling method in order to measure the electrical properties of titanium alloy pedicle screws used in spinal surgery and to compare it with other common methods of measurement. An experimental setup was devised to test the electrical resistance of two specimens of pedicle screws using four methods for coupling the sensing leads, including the use of multimeter probes, alligator clips, wrapped wires and encapsulation with thermo-retractable sleeves. The electrical resistance of the pedicle screw under testing was measured at a current of 10 mA for each coupling method, and the results compared. Our findings show that although widely used in electrical analysis, the alligator clips do not perform as well as the other methods, such as simple wrapping of wires around the screw or the direct application of multimeter probes. The use of thermo-retractable sleeves provides the lowest resistance and inter-quartile range and is closer to the tabled values for the screw's titanium alloy. Additionally, only this method allows the measurement of identical resistivity values between different screw models manufactured with the same titanium alloy. We then concluded that the use of wrapped wires encapsulated with thermo-retractable sleeves allow more accurate measurements of the pedicle screw's electrical properties.

  • 1151
  • 4542