2014
Autores
Roriz, P; Ferreira, J; Potes, JC; Oliveira, MT; Santos, JL; Simoes, JA; Frazao, O;
Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS
Abstract
The pressure measured in the intervertebral discs is a response to the loads acting on the spine. External loads, such as the reaction forces resulting from locomotion, manual handling and collisions are probably the most relevant in studying spine trauma. However, the physiological functions such as breathing and hearth rate also participate in subtle variations of intradiscal pressure that can be observed only in vivo at resting. Present work is an effort to measure the effect of breathing on intradiscal pressure of an anesthetized sheep.
2014
Autores
Passos, DJ; Silva, SO; Marques, MB; Frazao, O;
Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS
Abstract
This work presents a demonstration of the potential of fiber cavity ring-down for remote sensing, by using an OTDR to send impulses down similar to 20 km of optical fiber at the end of which the fiber ring cavity was placed. The OTDR showed almost no losses in the fiber, so other ring-down cavities could be spliced along the same fiber. To study the sensitivity of the cavity ring an intensity sensor based on a taper was placed in the ring and glued to a translation stage. A displacement of the stage imposes a curvature on the taper and an associated loss. The configuration had a sensitivity of (11.8 +/- 0.5) mu s/mm.
2014
Autores
Ferreira, MS; Santos, JL; Frazao, O;
Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS
Abstract
In this work a novel optical fiber sensor based on silica microspheres array is proposed. Different sensing heads are presented and compared, differing on the number of microspheres. These structures, ranging from arrays of one to five, are spliced in series. The sensor is subjected to different physical parameters, such as strain, temperature, refractive index and bending. Depending on the number of microspheres the sensitivities to strain and bending are different. The sensor also presents a high sensitivity to temperature of 20.3 pm/degrees C.
2014
Autores
Mouraa, JP; Baierl, H; Auguste, JL; Jamier, R; Roy, P; Santos, JL; Frazao, O;
Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A new configuration for volatile organic compound sensing is proposed. A sub-milimiter four-hole suspended core optical fiber tip, spliced to a standard single mode fiber, is dipped in a liquid volatile compound and the reflected signal is continuously interrogated. When the fiber is immersed in acetone it suffers a 1 4 dB signal drop. Different menisci form in each cladding cavity, with different evaporation times and rates. The signal restores its initial state not when the evaporation process is complete but after the collapse of a dominant meniscus.
2014
Autores
Pinto, AMR; Lopez Aldaba, A; Lopez Amo, M; Frazao, O; Santos, JL; Baptista, JM; Baierl, H; Auguste, JL; Jamier, R; Roy, P;
Publicação
Proceedings of SPIE - The International Society for Optical Engineering
Abstract
In this work, a hybrid Fabry-Perot interferometer based on a novel four-bridge microstructured fiber is presented and characterized. The characterization of this cavity is performed in the L-band using two different instruments: an optical spectrum analyzer and an optical backscatter reflectometer. The Fabry-Perot output signal presents linear variation with temperature changes (sensitivity 9.8-11.9 pm/°C), variation with the polarization states of light and high stability. © 2014 SPIE.
2014
Autores
Fernandes, CS; Rocco Giraldi, MTMR; Gouveia, CJ; Sousa, MJ; Costa, JCWA; Frazao, O; Jorge, PAS;
Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
In this work, a remote curvature sensor using a standard OTDR as the interrogation system is presented. This approach uses a core diameter mismatch sensor which is formed by a short section of a multimode fiber, with a length of 3 mm, sandwiched between two singlemode fibers. In this case, the attenuation of the optical signal will vary as the fiber is bent allowing interrogating the sensor with OTDR technology. Preliminary results indicate a resolution range of similar to 0.0003 cm(-1), sensitivity in the range of similar to-208.46 dB/cm(-1) and a variation of 2.67 dB in the OTDR trace within the bend radius range.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.