2022
Autores
Robalinho, P; Melo, M; Frazao, O; Ribeiro, ABL;
Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS
Abstract
The fibre optic current sensor demonstrated here uses the intrinsic temperature and wavelength dependence of the Verdet constant of a terbium gallium garnet (TGG) magneto-optic material and the two micro-optic linear polarizers attached, to simultaneously extract the values of temperature and the optical Faraday rotation (induced by the presence of the magnetic field due an electric current on a conductor) without any extra optical component attached to the optical sensor head. The simultaneous measurement is achieved by illuminating the sensor head with a broadband optical source and by careful signal processing of the originated channelled-spectrum, compensate the sensor's temperature dependence.
2022
Autores
Reis, J; V.Rodrigues, A; Robalinho, P; Novais, S; Maia, J; Marques, P; Roma, D; Salvans, J; Canal, M; Ramos, J; Gualani, V; Sisteré, S; Martín, V; Nofrarias, M; Silva, S; Frazão, O;
Publicação
EPJ Web of Conferences
Abstract
2022
Autores
Soares, B; Robalinho, P; Guerreiro, A; Frazao, O;
Publicação
PHOTONICS
Abstract
In this paper, we study the implementation of a secure key distribution system based on an ultra-long fiber laser with a bi-directional erbium-doped fiber amplifier. The resilience of the system was tested against passive attacks from an eavesdropper. A similarity was observed in the spectra for both secure configurations of the system and no signature that would allow an eavesdropper to obtain the secure state of the system was observed during the state transitions.
2025
Autores
Piaia, V; Robalinho, P; Soares, L; Novais, S; Ribeiro, AL; Frazao, O; Silva, S;
Publicação
29TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS
Abstract
A refractive index sensor was designed using a novel approach to sensing based on a cleaved standard fiber Bragg grating (FBG) at the grating region, which enables the FBG to interact with its surrounding environment. The sliced-FBG (SFBG) exhibits a variable phase shift in the reflection response due to the length of the last grating's pitch, which differs from the rest. At the SFBG, the signal is the result of interference between the reflected wave from the grating and the transmitted spectrum returned due to Fresnel reflection at the final pitch, and the intensity of this signal depends on the refractive index of the surrounding medium. Based on this phenomenon, an intensity-based refractive index sensor with self- referencing technique was employed in this experiment, whereby the grating peak maximum point served as the signal reference, while the minimum of the Fresnel peak from each measurement functioned as the signal input. The proposed sensor demonstrated the ability to measure refractive indices within the range of 1.333-1.339, with a resolution of approximate to 10(-3), and a minimum detectable value of 6x10(-4) RIU (the data yielded a linear response with R-2=0.990). This study presents an innovative data sensing approach compared to existing techniques found in literature, which typically employ wavelength variation in the reflected wave to extract the desired information.
2025
Autores
Robalinho, P; Piaia, V; Ribeiro, AL; Silva, S; Frazao, O;
Publicação
29TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS
Abstract
This work analyzes the sensitivity of an optical system consisting of two fiber Fabry-Perot ( FP) interferometers and the apparent increase in sensitivity due to the harmonics of the Vernier effect. Two scenarios are examined: (1) when the larger FP cavity acts as the sensor, and (2) when the smaller FP cavity acts as the sensor. The computation analysis reveals that in the first scenario, higher-order spectral harmonics yield greater sensitivity for maxima and minima of the same order. In the second scenario, however, the sensitivity remains constant and does not depend on the harmonic order. Moreover, it is demonstrated that the sensitivity curve is identical for both scenarios, regardless of the harmonic order. This outcome occurs because the use of spectral harmonics simply reduces the free-spectral range in certain situations, bringing the extrema closer to the maximum sensitivity condition (i.e., Delta L = 0) and thereby increasing sensitivity. Consequently, if points on the envelope other than maxima or minima are used, the sensitivity achieved is the same for both scenarios.
2025
Autores
Piaia, V; Robalinho, P; Rodrigues, A; Ribeiro, AL; Silva, S; Frazao, O;
Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS
Abstract
In this letter, we propose a method for utilizing the internal cavities of optical circulator devices-commonly referred to as parasitic cavities-as optical reference cavities. The method involves using an optical circulator operating at 1550 nm, illuminated by a light source at 1330 nm, thereby enhancing the amplitude of the interferometric signals generated by the internal optical cavities. The system was characterized by using both an Optical Spectrum Analyzer (OSA) and the Low-Coherence Interferometry (LCI) technique. Experimental results indicate that the Optical Path Difference (OPD) remains constant with varying aperture sizes, thereby confirming the feasibility of employing the optical circulator as a reference sensor. Finally, its performance as a reference sensor is demonstrated through its integration with an external cavity that functions as a displacement sensor.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.