Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Aurélio Campilho

2018

Radiologists' gaze characterization during lung nodule search in thoracic CT

Autores
Machado, M; Aresta, G; Leitao, P; Carvalho, AS; Rodrigues, M; Ramos, I; Cunha, A; Campilho, A;

Publicação
2018 1ST INTERNATIONAL CONFERENCE ON GRAPHICS AND INTERACTION (ICGI 2018)

Abstract
Lung cancer diagnosis is made by radiologists through nodule search in chest Computed Tomography (CT) scans. This task is known to be difficult and prone to errors that can lead to late diagnosis. Although Computer-Aided Diagnostic (CAD) systems are promising tools to be used in clinical practice, experienced radiologists continue to perform better diagnosis than CADs. This paper proposes a methodology for characterizing the radiologist's gaze during nodules search in chest CT scans. The main goals are to identify regions that attract the radiologists' attention, which can then be used for improving a lung CAD system, and to create a tool to assist radiologists during the search task. For that purpose, the methodology processes the radiologists' gaze and their mouse coordinates during the nodule search. The resulting data is then processed to obtain a 3D gaze path from which relevant attention studies can be derived. To better convey the found information, a reference model of the lung that eases the communication of the location of relevant anatomical/pathological findings is also proposed. The methodology is tested on a set of 24 real-practice gazes, recorded via an Eye tracker, from 3 radiologists.

2019

Wide Residual Network for Lung-Rads (TM) Screening Referral

Autores
Ferreira, CA; Aresta, G; Cunha, A; Mendonca, AM; Campilho, A;

Publicação
2019 6TH IEEE PORTUGUESE MEETING IN BIOENGINEERING (ENBENG)

Abstract
Lung cancer has an increasing preponderance in worldwide mortality, demanding for the development of efficient screening methods. With this in mind, a binary classification method using Lung-RADS (TM) guidelines to warn changes in the screening management is proposed. First, having into account the lack of public datasets for this task, the lung nodules in the LIDC-IDRI dataset were re-annotated to include a Lung-RADS (TM)-based referral label. Then, a wide residual network is used for automatically assessing lung nodules in 3D chest computed tomography exams. Unlike the standard malignancy prediction approaches, the proposed method avoids the need to segment and characterize lung nodules, and instead directly defines if a patient should be submitted for further lung cancer tests. The system achieves a nodule-wise accuracy of 0.87 +/- 0.02.

2019

Analysis of the performance of specialists and an automatic algorithm in retinal image quality assessment

Autores
Wanderley, DS; Araujo, T; Carvalho, CB; Maia, C; Penas, S; Carneiro, A; Mendonca, AM; Campilho, A;

Publicação
2019 6TH IEEE PORTUGUESE MEETING IN BIOENGINEERING (ENBENG)

Abstract
This study describes a novel dataset with retinal image quality annotation, defined by three different retinal experts, and presents an inter-observer analysis for quality assessment that can be used as gold-standard for future studies. A state-of-the-art algorithm for retinal image quality assessment is also analysed and compared against the specialists performance. Results show that, for 71% of the images present in the dataset, the three experts agree on the given image quality label. The results obtained for accuracy, specificity and sensitivity when comparing one expert against another were in the ranges [83.0 - 85.2]%, [72.7 - 92.9]% and [80.0 - 94.7]%, respectively. The evaluated automatic quality assessment method, despite not being trained on the novel dataset, presents a performance which is within inter-observer variability.

2018

MedAL: Accurate and Robust Deep Active Learning for Medical Image Analysis

Autores
Smailagic, A; Costa, P; Noh, HY; Walawalkar, D; Khandelwal, K; Galdran, A; Mirshekari, M; Fagert, J; Xu, SS; Zhang, P; Campilho, A;

Publicação
2018 17TH IEEE INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA)

Abstract
Deep learning models have been successfully used in medical image analysis problems but they require a large amount of labeled images to obtain good performance. However, such large labeled datasets are costly to acquire. Active learning techniques can be used to minimize the number of required training labels while maximizing the model's performance. In this work, we propose a novel sampling method that queries the unlabeled examples that maximize the average distance to all training set examples in a learned feature space. We then extend our sampling method to define a better initial training set, without the need for a trained model, by using Oriented FAST and Rotated BRIEF (ORB) feature descriptors. We validate MedAL on 3 medical image datasets and show that our method is robust to different dataset properties. MedAL is also efficient, achieving 80% accuracy on the task of Diabetic Retinopathy detection using only 425 labeled images, corresponding to a 32% reduction in the number of required labeled examples compared to the standard uncertainty sampling technique, and a 40% reduction compared to random sampling.

2019

EyeWeS: Weakly Supervised Pre-Trained Convolutional Neural Networks for Diabetic Retinopathy Detection

Autores
Costa, P; Araújo, T; Aresta, G; Galdran, A; Mendonça, AM; Smailagic, A; Campilho, A;

Publicação
PROCEEDINGS OF MVA 2019 16TH INTERNATIONAL CONFERENCE ON MACHINE VISION APPLICATIONS (MVA)

Abstract
Diabetic Retinopathy (DR) is one of the leading causes of preventable blindness in the developed world. With the increasing number of diabetic patients there is a growing need of an automated system for DR detection. We propose EyeWeS, a method that not only detects DR in eye fundus images but also pinpoints the regions of the image that contain lesions, while being trained with image labels only. We show that it is possible to convert any pre-trained convolutional neural network into a weakly-supervised model while increasing their performance and efficiency. EyeWeS improved the results of Inception V3 from 94:9% Area Under the Receiver Operating Curve (AUC) to 95:8% AUC while maintaining only approximately 5% of the Inception V3's number of parameters. The same model is able to achieve 97:1% AUC in a cross-dataset experiment.

2019

UNCERTAINTY-AWARE ARTERY/VEIN CLASSIFICATION ON RETINAL IMAGES

Autores
Galdran, A; Meyer, M; Costa, P; Mendonça; Campilho, A;

Publicação
2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019)

Abstract
The automatic differentiation of retinal vessels into arteries and veins (A/V) is a highly relevant task within the field of retinal image analysis. however, due to limitations of retinal image acquisition devices, specialists can find it impossible to label certain vessels in eye fundus images. In this paper, we introduce a method that takes into account such uncertainty by design. For this, we formulate the A/V classification task as a four-class segmentation problem, and a Convolutional Neural Network is trained to classify pixels into background, A/V, or uncertain classes. The resulting technique can directly provide pixelwise uncertainty estimates. In addition, instead of depending on a previously available vessel segmentation, the method automatically segments the vessel tree. Experimental results show a performance comparable or superior to several recent A/V classification approaches. In addition, the proposed technique also attains state-of-the-art performance when evaluated for the task of vessel segmentation, generalizing to data that, was not used during training, even with considerable differences in terms of appearance and resolution.

  • 15
  • 48