Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Jaime Cardoso

2007

A shortest path approach for staff line detection

Autores
Rebelo, A; Capela, A; Pinto da Costa, JF; Guedes, C; Carrapatoso, E; Cardoso, JS;

Publicação
AXMEDIS 2007: THIRD INTERNATIONAL CONFERENCE ON AUTOMATED PRODUCTION OF CROSS MEDIA CONTENT FOR MULTI-CHANNEL DISTRIBUTION, PROCEEDINGS

Abstract
Many music works produced in the past still exist only as original manuscripts or as photocopies. Preserving them entails their digitalization and consequent accessibility in a digital format easy-to-manage. The manual process to carry out this task is very time consuming and error prone. Optical music recognition (OMR) is a form of structured document image analysis where music symbols are isolated and identified so that the music can be conveniently processed. While OMR systems perform well on printed scores, current methods for reading handwritten musical scores by computers remain far from ideal. One of the fundamental stages of this process is the staff line detection. In this paper a new method for the automatic detection of music stave lines based on a shortest path approach is presented. Lines with some curvature, discontinuities, and inclination are robustly detected. The proposed algorithm behaves favourably when compared experimentally with well-established algorithms.

2007

Matched filtering and parameter estimation of ringdown waveforms

Autores
Berti, E; Cardoso, J; Cardoso, V; Cavaglia, M;

Publicação
PHYSICAL REVIEW D

Abstract
Using recent results from numerical relativity simulations of nonspinning binary black hole mergers, we revisit the problem of detecting ringdown waveforms and of estimating the source parameters, considering both LISA and Earth-based interferometers. We find that Advanced LIGO and EGO could detect intermediate-mass black holes of mass up to similar to 10(3)M(circle dot) out to a luminosity distance of a few Gpc. For typical multipolar energy distributions, we show that the single-mode ringdown templates presently used for ringdown searches in the LIGO data stream can produce a significant event loss (> 10% for all detectors in a large interval of black hole masses) and very large parameter estimation errors on the black hole's mass and spin. We estimate that more than similar to 10(6) templates would be needed for a single-stage multimode search. Therefore, we recommend a "two-stage" search to save on computational costs: single-mode templates can be used for detection, but multimode templates or Prony methods should be used to estimate parameters once a detection has been made. We update estimates of the critical signal-to-noise ratio required to test the hypothesis that two or more modes are present in the signal and to resolve their frequencies, showing that second-generation Earth-based detectors and LISA have the potential to perform no-hair tests.

2012

Long-term cosmetic changes after breast-conserving treatment of patients with stage I-II breast cancer and included in the EORTC 'boost versus no boost' trial

Autores
Immink, JM; Putter, H; Bartelink, H; Cardoso, JS; Cardoso, MJ; van der Hulst Vijgen, MHV; Noordijk, EM; Poortmans, PM; Rodenhuis, CC; Struikmans, H;

Publicação
ANNALS OF ONCOLOGY

Abstract
In breast cancer treated with breast-conserving radiotherapy, the influence of the boost dose on cosmetic outcome after long-term follow-up is unknown. We included 348 patients participating in the EORTC 'boost versus no boost' mega trial with a minimum follow-up of 6 years. Digitalised pictures were analysed using specific software, enabling quantification of seven relative asymmetry features associated with different aspects of fibrosis. After 3 years, we noted a statistically significantly poorer outcome for the boost patients for six features compared with those of the no boost patients. Up to 9 years of follow-up, results continued to worsen in the same magnitude for the both patient groups. We noted the following determinants for poorer outcome: (i) boost treatment, (ii) larger excision volumes, (iii) younger age, (iv) tumours located in the central lower quadrants of the breast and (v) a boost dose administered with photons. A boost dose worsens the change in breast appearance in the first 3 years. Moreover, the development of fibrosis associated with whole-breast irradiation, as estimated with the relative asymmetry features, is an ongoing process until (at least) 9 years after irradiation.

2002

Aesthetic evaluation of conservative breast cancer treatment: trying to optimize results

Autores
Cardoso, MJ; Preto, J; Queiros, H; Garrido, V; Moura, AJ; Pinto de Sousa, J; Ayres de Campos, D; Cardoso, J;

Publicação
EUROPEAN JOURNAL OF CANCER

Abstract

2005

Choosing observers for evaluation of aesthetic results in breast cancer conservative treatment

Autores
Cardoso, MJ; Santos, AC; Cardoso, J; Barros, H; De Oliveira, MC;

Publicação
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS

Abstract
Purpose: The subjective evaluation of aesthetic results in conservative breast cancer treatment has largely been used without questioning the observer's skills. The aim of this study was to evaluate interobserver agreement of the aesthetic results of breast cancer conservative treatment in three groups of observers with different levels of experience. Methods and Materials: Photographs were taken of 55 women who had undergone conservative unilateral breast cancer treatment and 5 control women with no breast disease. The images were then distributed to 13 observers who were divided into three groups according to their experience in breast cancer treatment: experienced, medium experienced, and inexperienced. They were first asked to distinguish the patients from the controls and for the patients to identify the operated side. Subsequently, they were asked to classify the aesthetic result as excellent, good, fair, or poor. The accuracy in identifying controls, patients, and side of treatment was calculated individually for all observers. The interobserver agreement for the aesthetic result was calculated using observed agreement and multiple K statistic (K) in each of the three groups. Results: Inexperienced observers performed significantly worse than experienced observers in identifying controls, patients, and the side of treatment. Agreement of the aesthetic result was significantly greater in the group of experienced observers (kappa = 0.59) than in the medium experienced (kappa = 0.35) and inexperienced (kappa= 0.33) observers. Conclusion: Previous experience in breast cancer conservative treatment should be considered a prerequisite for the evaluation of the aesthetic results. (C) 2005 Elsevier Inc.

2007

Turning subjective into objective: The BCCT.core software for evaluation of cosmetic results in breast cancer conservative treatment

Autores
Cardoso, MJ; Cardoso, J; Amaral, N; Azevedo, I; Barreau, L; Bernardo, M; Christie, D; Costa, S; Fitzal, F; Fougo, JL; Johansen, J; Macmillan, D; Mano, MP; Regolo, L; Rosa, J; Teixeira, L; Vrieling, C;

Publicação
BREAST

Abstract
Twelve expert observers from nine different countries convened in a workshop to evaluate the validity of the Breast Cancer Conservative Treatment. Cosmetic results (BCCT.core) software, an objective method for the aesthetic evaluation of breast cancer conservative treatment. Experts were initially asked to subjectively classify the aesthetic results of 30 photographed cases submitted to breast cancer conservative treatment according to the four-point Harris scale. It was pre-established that if at least two-thirds [Cardoso MJ, Cardoso J, Santos AC, Barros H, Oliveira MC. Interobserver agreement and consensus over the esthetic evaluation of conservative treatment for breast cancer. Breast 2005] of participants provided the same classification this would be considered a consensual evaluation for that case. For cases where such agreement was not reached, consensus was obtained using a nominal group technique. Experts then individually performed objective evaluation of the same set of photographs using the BCCT.core software. This provides an automatic rating of aesthetic results, once scale and reference points in the photograph have been chosen. Agreement between observers, between each observer and the consensus, for computer evaluation obtained by the different participants and between software and consensus was calculated using multiple kappa (k) and weighted kappa (wk) statistics. In the subjective assessment, first-round consensus was achived in 17 (57%) cases. Overall interobserver agreement was fair to moderate (k = 0.40, wk = 0.57). In the objective assessment there was a higher level of concordance between participants (k = 0.86, wk = 0.90). Agreement between software and consensus classification was fair (k = 0.34, wk = 0.53), but was higher in the 17 cases that reached first-round consensus (k = 0.60, wk = 0.73). Merging the two middle classes of the Harris scale, to form a three-point scale, led to an improvement of all non-weighted measures of agreement. These results show that the BCCT.core software provides consistent evaluation of cosmesis. It has the potential to become a gold standard method for assessment of breast cosmesis in clinical trials, as it can be used simultaneously by a panel of observers from different parts of the world to provide more reliable assessments than has been possible previously.

  • 57
  • 66