2015
Autores
Oliveira, J; Oliveira, C; Cardoso, B; Sultan, MS; Coimbra, MT;
Publicação
2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)
Abstract
Acoustic heart signals are generated by a turbulence effect created when the heart valves snap shut, and therefore carrying significant information of the underlying functionality of the cardiovascular system. In this paper, we present a method for heart murmur classification divided into three major steps: a) features are extracted from the heart sound; b) features are selected using a Backward Feature Selection algorithm; c) signals are classified using a K-nearest neighbor's classifier. A new set of fractal features are proposed, which are based on the distinct signatures of complexity and self-similarity registered on the normal and pathogenic cases. The experimental results show that fractal features are the most capable of describing the non-linear structure and the underlying dynamics of heart sounds among the all feature families tested. The classification results achieved for the mitral auscultation spot (88% of accuracy) are in agreement with the current state of the art methods for heart murmur classification.
2019
Autores
Renna, F; Oliveira, J; Coimbra, MT;
Publicação
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS
Abstract
This paper studies the use of deep convolutional neural networks to segment heart sounds into their main components. The proposed methods are based on the adoption of a deep convolutional neural network architecture, which is inspired by similar approaches used for image segmentation. Different temporal modeling schemes are applied to the output of the proposed neural network, which induce the output state sequence to be consistent with the natural sequence of states within a heart sound signal (S1, systole, S2, diastole). In particular, convolutional neural networks are used in conjunction with underlying hidden Markov models and hidden semi-Markov models to infer emission distributions. The proposed approaches are tested on heart sound signals from the publicly available PhysioNet dataset, and they are shown to outperform current state-of-the-art segmentation methods by achieving an average sensitivity of 93.9 and an average positive predictive value of 94 in detecting S1 and S2 sounds.
2019
Autores
Renna, F; Illanes, A; Oliveira, J; Esmaeili, N; Friebe, M; Coimbra, MT;
Publicação
2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)
Abstract
This paper studies the use of non-invasive acoustic emission recordings for clinical device tracking. In particular, audio signals recorded at the proximal end of a needle are used to detect perforation events that occur when the needle tip crosses internal tissue layers. A comparative study is performed to assess the capacity of different features and envelopes in detecting perforation events. The results obtained from the considered experimental setup show a statistically significant correlation between the extracted envelopes and the perforation events, thus leading the way for future development of perforation detection algorithms.
2021
Autores
Oliveira, M; Oliveira, J; Camacho, R; Ferreira, C;
Publicação
BIOSIGNALS: PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES - VOL 4: BIOSIGNALS
Abstract
Cardiovascular diseases are one of the leading causes of death in the world. In low income countries, heart auscultation is of capital importance since it is an efficient and low cost method to monitor the heart. In this paper, we propose a multi-spot system that aims to detect cardiac anomalies and to support a diagnosis in remote areas with limited heath care response. Our proposed solutions exploits data collected from the four main auscultation spots: Mitral, Pulmonary, Tricuspid and Aorta in a asynchronous way. From the several multi-spot systems implemented, the best results were obtained using a bi-modal system that only processes the Mitral and the Pulmonary spot simultaneously. Using these two spots we have achieved an accuracy between 85.7% (smallest value, using ANN) and the best value of 91.4% (obtained with a logistic regression algorithm). Taking into a account the pediatric population and the incident cardiac pathologies, it happens to be the spots where the observed murmurs were most audible. We have also find out that when using four auscultation spots, the choice of the algorithm is of secondary priority, which does not seem to be the case for a single auscultation spot system. With one single auscultation we have an average of 4% of difference between the results obtained with the algorithms and with four auscultation spots we have a smaller average of 2.1%.
2021
Autores
Faustino, P; Oliveira, J; Coimbra, M;
Publicação
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC)
Abstract
Respiratory diseases are among the leading causes of death worldwide. Preventive measures are essential to avoid and increase the odds of a successful recovery. An important screening tool is pulmonary auscultation, an inexpensive, noninvasive and safe method to assess the mechanics and dynamics of the lungs. On the other hand, it is a difficult task for a human listener since some lung sound events have a spectrum of frequencies outside of the human hearing ability. Thus, computer assisted decision systems might play an important role in the detection of abnormal sounds, such as crackle or wheeze sounds. In this paper, we propose a novel system, which is not only able to detect abnormal lung sound events, but it is also able to classify them. Furthermore, our system was trained and tested using the publicly available ICBHI 2017 challenge dataset, and using the metrics proposed by the challenge, thus making our framework and results easily comparable. Using a Mel Spectrogram as an input feature for our convolutional neural network, our system achieved results in line with the current state of the art, an accuracy of 43 %, and a sensitivity of 51%.
2021
Autores
Oliveira, J; Nogueira, D; Renna, F; Ferreira, C; Jorge, AM; Coimbra, M;
Publicação
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC)
Abstract
Cardiac auscultation is the key screening procedure to detect and identify cardiovascular diseases (CVDs). One of many steps to automatically detect CVDs using auscultation, concerns the detection and delimitation of the heart sound boundaries, a process known as segmentation. Whether to include or not a segmentation step in the signal classification pipeline is nowadays a topic of discussion. Up to our knowledge, the outcome of a segmentation algorithm has been used almost exclusively to align the different signal segments according to the heartbeat. In this paper, the need for a heartbeat alignment step is tested and evaluated over different machine learning algorithms, including deep learning solutions. From the different classifiers tested, Gate Recurrent Unit (GRU) Network and Convolutional Neural Network (CNN) algorithms are shown to be the most robust. Namely, these algorithms can detect the presence of heart murmurs even without a heartbeat alignment step. Furthermore, Support Vector Machine (SVM) and Random Forest (RF) algorithms require an explicit segmentation step to effectively detect heart sounds and murmurs, the overall performance is expected drop approximately 5% on both cases.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.