2014
Autores
Pereira, T; Santos, I; Oliveira, T; Vaz, P; Pereira, T; Santos, H; Pereira, H; Correia, C; Cardoso, J;
Publicação
MEDICAL ENGINEERING & PHYSICS
Abstract
The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe that measures carotid artery distension profiles are compared with the waveforms of the pulse pressure acquired by intra-arterial catheter invasive measurement in the ascending aorta. Measurements were performed in a study population of 16 patients who had undergone cardiac catheterization. The hemodynamic parameters: area under the curve (AUC), the area during systole (AS) and the area during diastole (AD), their ratio (AD/AS) and the ejection time index (ETI), from invasive and non-invasive measurements were compared. The results show that the pressure waveforms obtained by the two methods are similar, with 13% of mean value of the root mean square error (RMSE). Moreover, the correlation coefficient demonstrates the strong correlation. The comparison between the AUCs allows the assessment of the differences between the phases of the cardiac cycle. In the systolic period the waveforms are almost equal, evidencing greatest clinical relevance during this period. Slight differences are found in diastole, probably due to the structural arterial differences. The optical probe has lower variability than the invasive system (13% vs 16%). This study validates the capability of acquiring the arterial pulse waveform with a non-invasive method, using a non-contact optical probe at the carotid site with residual differences from the aortic invasive measurements.
2014
Autores
Vaz, P; Capela, D; Pereira, T; Correia, C; Ferreira, R; Humeau Heurtier, A; Cardoso, J;
Publicação
SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A system using laser speckle effect is proposed to segment images reflecting vibration movements of diffuse targets. Longitudinal movements are difficult to identify when simple imaging systems are used. The proposed system produces a two dimensional segmentation of the target and it is sensitive to longitudinal movements. The speckle effect, produced when coherent light is reflected and interferes when hitting rough surfaces, can be used in order to accomplish this purpose. A pattern with high and low intensity spots is observed depending on the illuminated scene. In our optical system, two silicone membranes are illuminated using a beam expanded laser source and their patterns are recorded using a video camera. One of the membranes experiences a longitudinal controlled movement while the remaining scene is still. Speckle data is processed using a temporal gradient and a regional entropy computation. This method produces a binary individual pixel classification. Four sets of parameters have been tested for the entropy computation and the area under the receiver operating characteristic (ROC) curve was used to select the best one. The selected set-up achieved a ROC value of 0.9879. A data set with 12 different membrane velocities was used to define the threshold that maximizes the classifier accuracy. This threshold was applied to a validation data-set composed by 4 sinusoidal movements with distinct velocities. The accuracy of this technique has achieved values between 92% and 97%. The results show that the target was accurately identified with the optical non-contact apparatus and the developed algorithm.
2014
Autores
Pereira, T; Santos, IP; Pereira, T; Santos, H; Almeida, V; Pereira, HC; Correia, CMBA; Cardoso, JMR;
Publicação
BIOSIGNALS
Abstract
The hemodynamic parameters extracted from pulse pressure waveform, by pulse wave analysis (PWA) and pulse wave velocity (PWV) are strong independent predictors of cardiovascular morbidity. The aim of this study is to investigate the reproducibility of pulse pressure profile and arterial stiffness indicators, i.e., Augmentation Index (AIx), Subendocardial Viability Ratio (SEVR), maximum rate of pressure change (dP/dtmax), Ejection Time Index (ETI), as measured using a contactless optical system. Reproducibility was evaluated in 13 healthy subjects by two senior operators ('A' and 'B') that acquired signals in alternate order (ABAB or BABA). The PWV result showed a good inter and intra-operator reproducibility. The mean difference between the two operators is 0.1570 m/s with a SD of 0.8160 m/s, this difference represents approximately 3.49% of the arithmetic average of the means obtained by each operator per trial. Between trials, differences of less than 8% of the mean PWV value for each operator were obtained. PWA repeatability results are considered high for HR, strong for Aix and moderate for dP/dtmax. The newly developed optical system showed good reproducibility as evaluated by both inter-operator and intraoperator methods. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
2014
Autores
Correia C.; Raynaud H.F.; Kulcsar C.; Conan J.M.;
Publicação
2009 European Control Conference, ECC 2009
Abstract
Adaptive Optics (AO) systems use a Deformable Mirror (DM) to counter in real-time the nefarious effects of atmospheric turbulence on ground-based telescopes images. This article presents a brief historical overview of AO design, seen as a strongly multi-variable minimum-variance (MVP) disturbance rejection problem associated with a hybrid continuous/ discrete time MV control problem. It is shown that for a wide class of LTI DM and turbulence models, this hybrid MV problem can be transformed into an equivalent discrete-time LQG formulation. A discrete-time stochastic model enables to compute the optimal control in standard reconstructed feedback form and to evaluate performance degradation for simpler suboptimal solutions. An example to tip-tilt DM control for the European Extremely Large Telescope (E-ELT) is presented.
2014
Autores
Lamb, M; Andersen, DR; Véran, J; Correia, C; Herriot, G; Rosensteiner, M; Fiege, J;
Publicação
Adaptive Optics Systems IV
Abstract
2014
Autores
Correia, CM; Teixeira, J;
Publicação
Journal of the Optical Society of America A: Optics and Image Science, and Vision
Abstract
Computationally efficient wave-front reconstruction techniques for astronomical adaptive-optics (AO) systems have seen great development in the past decade. Algorithms developed in the spatial-frequency (Fourier) domain have gathered much attention, especially for high-contrast imaging systems. In this paper we present the Wiener filter (resulting in the maximization of the Strehl ratio) and further develop formulae for the anti-aliasing (AA) Wiener filter that optimally takes into account high-order wave-front terms folded in-band during the sensing (i.e., discrete sampling) process. We employ a continuous spatial-frequency representation for the forward measurement operators and derive the Wiener filter when aliasing is explicitly taken into account. We further investigate and compare to classical estimates using least-squares filters the reconstructed wave-front, measurement noise, and aliasing propagation coefficients as a function of the system order. Regarding high-contrast systems, we provide achievable performance results as a function of an ensemble of forward models for the Shack-Hartmann wave-front sensor (using sparse and nonsparse representations) and compute point-spread-function raw intensities. We find that for a 32 × 32 single-conjugated AOs system the aliasing propagation coefficient is roughly 60% of the least-squares filters, whereas the noise propagation is around 80%. Contrast improvements of factors of up to 2 are achievable across the field in the H band. For current and next-generation high-contrast imagers, despite better aliasing mitigation, AA Wiener filtering cannot be used as a standalone method and must therefore be used in combination with optical spatial filters deployed before image formation actually takes place. © 2014 Optical Society of America.