2012
Autores
Silva, S; Coelho, L; Santos, JL; Malcata, FX; Becker, M; Rothhardt, M; Bartelt, H; Frazao, O;
Publicação
Optics InfoBase Conference Papers
Abstract
An optical fiber sensor based on a tapered-FBG coated with 150 nm-thick Pd film is proposed for hydrogen pressure detection. The FBG was written in a 50 µm-diameter tapered fiber by DUV femtosecond laser technology. A second FBG was inscribed in the untapered fiber region for temperature compensation. The sensing head was able to detect the variation of hydrogen pressure in the range 0-780 kPa and a maximum sensitivity of 0.15 pm/kPa was achieved. © 2012 OSA.
2012
Autores
Martins, H; Marques, MB; Jorge, P; Cordeiro, CMB; Frazao, O;
Publicação
MICRO-STRUCTURED AND SPECIALTY OPTICAL FIBRES
Abstract
An intensity curvature sensor using a Photonic Crystal Fiber (PCF) with three coupled cores is proposed. The three cores were aligned and there was an air hole between each two consecutive cores. The fiber had a low air filling fraction, which means that the cores remain coupled in the wavelength region studied. Due to this coupling interference is obtained in the fiber output even if just a single core is illuminated. A configuration using transmission interrogation, which used a section fiber with 0.08 m of PCF as the sensing head, and a configuration using reflection interrogation, which used a section fiber with 0.13 m of PCF as the sensing head, were characterized and compared for curvature sensing. When the fiber is bended along the plane of the cores, one of the lateral cores will be stretched and the other compressed. This changes the coupling between the three cores, changing the optical power intensity. The sensibility of the sensing head was strongly dependent on the direction of bending, having its maximum when the bending direction was along the plane of the cores. A maximum curvature sensitivity of 1.8 dB. m was demonstrated between 0 m and 2.8 m.
2012
Autores
Martins, H; Marques, MB; Jorge, P; Cordeiro, CMB; Frazao, O;
Publicação
OPTICS COMMUNICATIONS
Abstract
An intensity curvature sensor using a Photonic Crystal Fiber (PCF) with three coupled cores is proposed. The three cores were aligned and there was an air hole between each two consecutive cores. The fiber had a low air filling fraction, which means that the cores remain coupled in the wavelength region studied. Due to this coupling, interference is obtained in the fiber output even if just a single core is illuminated. A configuration using reflection interrogation, which used a section fiber with 0.13 m as the sensing head, was characterized for curvature sensing. When the fiber is bended along the plane of the cores, one of the lateral cores will be stretched and the other compressed. This changes the coupling coefficient between the three cores, changing the output optical power intensity. The sensitivity of the sensing head was strongly dependent on the direction of bending, having its maximum when the bending direction was along the plane of the cores. A maximum curvature sensitivity of 2.0 dB/m(-1) was demonstrated between 0 m and 2.8 m.
2012
Autores
Silva, S; Pachon, EGP; Franco, MAR; Hayashi, JG; Xavier Malcata, FX; Frazao, O; Jorge, P; Cordeiro, CMB;
Publicação
APPLIED OPTICS
Abstract
The proposed sensing device relies on the self-imaging effect that occurs in a pure silica multimode fiber (coreless MMF) section of a single-mode-multimode-single-mode (SMS)-based fiber structure. The influence of the coreless-MMF diameter on the external refractive index (RI) variation permitted the sensing head with the lowest MMF diameter (i.e., 55 mu m) to exhibit the maximum sensitivity (2800 nm/RIU). This approach also implied an ultrahigh sensitivity of this fiber device to temperature variations in the liquid RI of 1.43: a maximum sensitivity of -1880 pm/degrees C was indeed attained. Therefore, the results produced were over 100-fold those of the typical value of approximately 13 pm/degrees C achieved in air using a similar device. Numerical analysis of an evanescent wave absorption sensor was performed, in order to extend the range of liquids with a detectable RI to above 1.43. The suggested model is an SMS fiber device where a polymer coating, with an RI as low as 1.3, is deposited over the coreless MMF; numerical results are presented pertaining to several polymer thicknesses in terms of external RI variation. (C) 2012 Optical Society of America
2012
Autores
Ribeiro, AR; Martinho, I; Tillak, JB; Bernacka Wojcik, I; Barata, D; Jorge, PAS; Aguas, H; Oliva, AG;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
In this paper an optofluidic chip for simultaneous determination of refractive index and acquisition of absorption or fluorescent spectra is described. The system comprises a microfluidic channel with multiple inlet/outlet for sample handling and a dual fiber optic probe, standing face to face across the channel, for the optical measurements. An FBG based Fabry Perot cavity, and a Braggmeter, allow for interferometric measurement of the refractive index while external illumination and a multimode fiber enable acquisition of the absorption/fluorescence spectra with a CCD spectrometer. Preliminary results showing the viability of simultaneous measurement are obtained from the characterization of mixed samples with distinct refractive index and dye concentrations.
2012
Autores
Silva, RM; Chesini, G; Gouveia, CJ; Lobo Ribeiro, ABL; Frazao, O; Cordeiro, CMB; Jorge, PAS;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
In this work a magnetic field sensor based on an FBG coated with a thin film of Terfenol-D is presented. The sensor was tested with two optical interrogation systems: one, a scanning laser system with a 1 pm resolution, and the other a differential white light interferometer (WLI). The results obtained in the magnetic field range of 20 mT to 100 mT, show the possibility of increasing the magnetic field measurement resolution, with temperature fluctuations invariance, by a factor of 4.5 when using the WLI system.