Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Orlando Frazão

2024

Enhanced Sensitivity in Optical Sensors through Self-Image Theory and Graphene Oxide Coating

Autores
Cunha, C; Monteiro, C; Vaz, A; Silva, S; Frazao, O; Novais, S;

Publicação
SENSORS

Abstract
This paper presents an approach to enhancing sensitivity in optical sensors by integrating self-image theory and graphene oxide coating. The sensor is specifically engineered to quantitatively assess glucose concentrations in aqueous solutions that simulate the spectrum of glucose levels typically encountered in human saliva. Prior to sensor fabrication, the theoretical self-image points were rigorously validated using Multiphysics COMSOL 6.0 software. Subsequently, the sensor was fabricated to a length corresponding to the second self-image point (29.12 mm) and coated with an 80 mu m/mL graphene oxide film using the Layer-by-Layer technique. The sensor characterization in refractive index demonstrated a wavelength sensitivity of 200 +/- 6 nm/RIU. Comparative evaluations of uncoated and graphene oxide-coated sensors applied to measure glucose in solutions ranging from 25 to 200 mg/dL showed an eightfold sensitivity improvement with one bilayer of Polyethyleneimine/graphene. The final graphene oxide-based sensor exhibited a sensitivity of 10.403 +/- 0.004 pm/(mg/dL) and demonstrated stability with a low standard deviation of 0.46 pm/min and a maximum theoretical resolution of 1.90 mg/dL.

2024

A century on diameter measurement techniques in cylindrical structures

Autores
Cardoso, VHR; Caldas, P; Giraldi, MTR; Cernadas, ML; Fernandes, CS; Frazao, O; Costa, JCWA; Santos, JL;

Publicação
MEASUREMENT SCIENCE AND TECHNOLOGY

Abstract
This work addresses the historical development of techniques and methodologies oriented to the measurement of the internal diameter of transparent tubes since the original contributions of Anderson and Barr published in 1923 in the first issue of Measurement Science and Technology. The progresses on this field are summarized and highlighted the emergence and significance of the measurement approaches supported by the optical fiber.

2024

Optimizing Graphene Oxide Saturable Absorbers for Short Pulse Generation in Fiber Lasers: Characterization and Aging Assessment

Autores
Monteiro, CS; Perez-Herrera, RA; Silva, NA; Silva, SO; Frazao, O;

Publicação
FIBER LASERS AND GLASS PHOTONICS: MATERIALS THROUGH APPLICATIONS IV

Abstract
The generation of short pulses in fiber lasers using saturable absorbers made of graphene oxide (GO), focusing on film thickness, was studied and optimized. The saturable absorber comprised a GO thin film deposited onto a single-mode fiber using the spray coating technique. Water-dispersed GO with a concentration of 4 mg/mL, characterized by a high proportion of monolayer flakes, was employed. This thin film was integrated into a cavity ring laser featuring an erbium-doped fiber amplifier (EDFA), resulting in a fiber laser emitting at a central emission wavelength of approximately 1564 nm and having a total cavity length of approximately 120 m. By controlling intracavity polarization, short-pulsed light was generated through mode-locking, Q switching, or a combination of both regimes. This work presents a comprehensive characterization of the cavity ring laser operating under the mode-locking regime. It encompasses an analysis of the spectral behavior, focusing on the evolution of the Kelly's sidebands with increasing pump power, as well as an assessment of its temporal stability. Moreover, the effects of the aging of the saturable absorber material were studied after a time period of 6 months after the fabrication. It was observed that the general characteristics of spectral signal of the laser were maintained, with long-term stability .

2024

Coreless Silica Fiber Sensor based on Self-Image Theory and coated with Graphene Oxide

Autores
Cunha, C; Monteiro, C; Vaz, A; Silva, S; Frazao, O; Novais, S;

Publicação
OPTICAL SENSING AND DETECTION VIII

Abstract
This work provides a method that combines graphene oxide coating and self-image theory to improve the sensitivity of optical sensors. The sensor is designed specifically to measure the amount of glucose present quantitatively in aqueous solutions that replicate the range of glucose concentrations found in human saliva. COMSOL Multiphysics 6.0 was used to simulate the self-imaging phenomenon using a coreless silica fiber (CSF). For high-quality self-imaging, the second and fourth self-imaging points are usually preferred because of their higher coupling efficiency, which increases the sensor sensitivity. However, managing the fourth self-image is more difficult because it calls for a longer CSF length. As a result, the first and second self-image points were the focus of the simulation in this work. After the simulation, using the Layerby-Layer method, the sensor was constructed to a length that matched the second self-image point (29.12 mm) and coated with an 80 mu m/mL graphene oxide layer. When comparing uncoated and graphene oxide-covered sensors to measure glucose in liquids ranging from 25 to 200 mg/dL, one bilayer of polyethyleneimine/graphene demonstrated an eight-fold improvement in sensitivity. The final sensor, built on graphene oxide, showed stability with a low standard deviation of 0.6 pm/min. It also showed sensitivity at 10.403 +/- 0.004 pm/(mg/dL) with a limit of detection of 9.15 mg/dL.

2024

Glucose concentration detection using a low-cost Raman Spectroscopy Kit

Autores
Cunha, C; Silva, S; Frazao, O; Novais, S;

Publicação
EOS ANNUAL MEETING, EOSAM 2024

Abstract
Raman technology offers a cutting-edge approach to measuring glucose solutions, providing precise and non-invasive analysis. By probing the vibrational energy levels of molecular bonds, Raman technology generates a unique spectral fingerprint that allows for the accurate determination of glucose concentrations. This study proposes the use of Raman spectroscopy to identify different glucose concentrations through the detection of Raman fingerprints. As expected, higher concentrations of glucose in the solution conducted to higher peak bands, indicating more glucose molecules interacting with light and consequently increasing the magnitude of inelastic scattering. This non-destructive approach preserves sample integrity and facilitates rapid analysis, making it suitable for various applications in biomedical research, pharmaceutical development, and food science.

2024

Low Coherence Interferometry Measurement: An Algorithm for fast processing with low noise and phase linearisation

Autores
Robalinho, P; Rodrigues, A; Novais, S; Ribeiro, ABL; Silva, S; Frazao, O;

Publicação
EOS ANNUAL MEETING, EOSAM 2024

Abstract
This work proposes a signal processing algorithm to analyse the optical signal from a Low Coherence Interferometric (LCI) system. The system uses a Mach-Zehnder (MZ) interferometer to interrogate a Fabry-Perot cavity, working as an optical sensor. This algorithm is based on the correlation and convolution operations, which allows the signal to be reconstructed based on itself, as well as, on the linearization of the signal phase, allowing the non-linearities of the actuator incorporated on the MZ interferometer to be compensated. The results show a noise reduction of 30 dB in the signal acquired. As a result, a reduction of 8.2 dB in the uncertainty of the measurement of the physical measurand is achieved. It is also demonstrated that the phase linearization made it possible to obtain a coefficient of determination (namely, R-squared) higher than 0.999.

  • 84
  • 86