2010
Autores
Palmeira, J; Lopes, L; Silva, AJ; Jorge, PAS; Oliva, A;
Publicação
Diffusion and Defect Data Pt.B: Solid State Phenomena
Abstract
In the recent years, sol-gel films have been intensively used in optical sensors configurations. Due to its hydrophobic nature, ormosil films have been reported to be a promising supporting matrix for oxygen sensing dyes for measurements in aqueous media. In this work, the impact of the sol-gel host fabrication parameters in the characteristics of the resulting oxygen sensing membranes is thoroughly evaluated. Different combinations of organic-inorganic precursors, with different aging times, were tested as oxygen sensors. All the solution were doped with ruthenium complex Ru(II)-tris(4,7-diphenyl-1,10- phenanthroline) to introduce oxygen sensitivity. Thin films were produced by dip coating of glass slides. The oxygen sensitive films were tested in aqueous phase in equilibrium with different oxygen gas compositions, using a phase-modulation technique. Sensor performance parameters such as Stern-Volmer constant, quenching efficiency and lifetime response are reported. The data obtained clearly indicates that increased aging times and longer organic groups produce sensors with the highest sensitivity to dissolved oxygen. From all sol-gel films produced, the BTEOS:TEOS (1:1) mixture is the most promising for sensor construction. © (2010) Trans Tech Publications.
2012
Autores
Silva, S; Pachon, EGP; Franco, MAR; Hayashi, JG; Xavier Malcata, FX; Frazao, O; Jorge, P; Cordeiro, CMB;
Publicação
APPLIED OPTICS
Abstract
The proposed sensing device relies on the self-imaging effect that occurs in a pure silica multimode fiber (coreless MMF) section of a single-mode-multimode-single-mode (SMS)-based fiber structure. The influence of the coreless-MMF diameter on the external refractive index (RI) variation permitted the sensing head with the lowest MMF diameter (i.e., 55 mu m) to exhibit the maximum sensitivity (2800 nm/RIU). This approach also implied an ultrahigh sensitivity of this fiber device to temperature variations in the liquid RI of 1.43: a maximum sensitivity of -1880 pm/degrees C was indeed attained. Therefore, the results produced were over 100-fold those of the typical value of approximately 13 pm/degrees C achieved in air using a similar device. Numerical analysis of an evanescent wave absorption sensor was performed, in order to extend the range of liquids with a detectable RI to above 1.43. The suggested model is an SMS fiber device where a polymer coating, with an RI as low as 1.3, is deposited over the coreless MMF; numerical results are presented pertaining to several polymer thicknesses in terms of external RI variation. (C) 2012 Optical Society of America
2012
Autores
Ribeiro, AR; Martinho, I; Tillak, JB; Bernacka Wojcik, I; Barata, D; Jorge, PAS; Aguas, H; Oliva, AG;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
In this paper an optofluidic chip for simultaneous determination of refractive index and acquisition of absorption or fluorescent spectra is described. The system comprises a microfluidic channel with multiple inlet/outlet for sample handling and a dual fiber optic probe, standing face to face across the channel, for the optical measurements. An FBG based Fabry Perot cavity, and a Braggmeter, allow for interferometric measurement of the refractive index while external illumination and a multimode fiber enable acquisition of the absorption/fluorescence spectra with a CCD spectrometer. Preliminary results showing the viability of simultaneous measurement are obtained from the characterization of mixed samples with distinct refractive index and dye concentrations.
2012
Autores
Silva, RM; Chesini, G; Gouveia, CJ; Lobo Ribeiro, ABL; Frazao, O; Cordeiro, CMB; Jorge, PAS;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
In this work a magnetic field sensor based on an FBG coated with a thin film of Terfenol-D is presented. The sensor was tested with two optical interrogation systems: one, a scanning laser system with a 1 pm resolution, and the other a differential white light interferometer (WLI). The results obtained in the magnetic field range of 20 mT to 100 mT, show the possibility of increasing the magnetic field measurement resolution, with temperature fluctuations invariance, by a factor of 4.5 when using the WLI system.
2012
Autores
Layeghi, A; Zibaii, MI; Sadeghi, J; Frazao, O; Jorge, PAS; Latifi, H;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
A high-birefringent fiber (HBF) was tapered as adiabatic in sequence steps by utilizing a CO2 laser and its birefringence was measured in fiber loop mirror (FLM) setup. The birefringence of tapered section and total sensor was obtained to be -8.02x10(-2), and 2.46x10(-4), respectively. Then, refractive index (RI) sensitivity increased and temperature sensitivity of the tapered Hi-Bi fiber (THBF) decreased. The sensitivity of the proposed FLM interferometer for RI changes in the range from 1.3380 to 1.3470 was measured to be 389.85 nm/RIU. The temperature sensitivity in the range from 50 degrees C to 90 degrees C was measured to be -1.19nm/degrees C.
2012
Autores
Zibaii, MI; Nouri, S; Sadeghi, J; Latifi, H; Jorge, PAS; Schuster, K; Kobelke, J; Frazao, O;
Publicação
22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3
Abstract
In this work, fiber in-line Mach-Zehnder Interferometer (MZI) based on triangular-shape suspended core fibers (SCFs) is investigated. The sensitivity of the sensing head was determined for pressure and temperature, respectively. The sensitivities are 0.4 pm/psi and 13 pm/psi for longitudinal and radial pressure, respectively. The sensing head was also subjected to temperature and presented very low sensitivity.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.