2016
Autores
Sequeira A.F.; Chen L.; Ferryman J.; Alonso-Fernandez F.; Bigun J.; Raja K.B.; Raghavendra R.; Busch C.; Wild P.;
Publicação
Lecture Notes in Informatics (LNI), Proceedings - Series of the Gesellschaft fur Informatik (GI)
Abstract
This work presents a novel dual-spectrum database containing both iris and periocular images synchronously captured from a distance and within a realistic indoor environment. This database was used in the 1st Cross-Spectrum Iris/Periocular Recognition Competition (Cross-Eyed 2016). This competition aimed at recording recent advances in cross-spectrum iris and periocular recognition. Six submissions were evaluated for crossspectrum periocular recognition, and three for iris recognition. The submitted algorithms are briefly introduced. Detailed results are reported in this paper, and comparison of the results is discussed.
2016
Autores
Pereira, T; Paiva, JS; Correia, C; Cardoso, J;
Publicação
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
Abstract
The measurement and analysis of the arterial pulse waveform (APW) are the means for cardiovascular risk assessment. Optical sensors represent an attractive instrumental solution to APW assessment due to their truly non-contact nature that makes the measurement of the skin surface displacement possible, especially at the carotid artery site. In this work, an automatic method to extract and classify the acquired data of APW signals and noise segments was proposed. Two classifiers were implemented: k-nearest neighbours and support vector machine (SVM), and a comparative study was made, considering widely used performance metrics. This work represents a wide study in feature creation for APW. A pool of 37 features was extracted and split in different subsets: amplitude features, time domain statistics, wavelet features, cross-correlation features and frequency domain statistics. The support vector machine recursive feature elimination was implemented for feature selection in order to identify the most relevant feature. The best result (0.952 accuracy) in discrimination between signals and noise was obtained for the SVM classifier with an optimal feature subset .
2016
Autores
Pereira, T; Nogueira Silva, C; Simoes, R;
Publicação
INFRARED PHYSICS & TECHNOLOGY
Abstract
Body skin temperature is a useful parameter for diagnosing diseases and infrared thermography can, be a powerful tool in providing important information to detect body temperature changes in a noninvasive way. The aim of this work was to study the pattern of skin temperature during pregnancy, to establish skin temperature reference values and to find correlations between these and the pregnant population characteristics. Sixty-one healthy pregnant women (mean age 30.6 +/- 5.1 years) in the 8th-40th gestational week with normal pregnancies were examined in 31 regions of interest (ROI). The ROIs were defined all over the body in order to determine the most influenced by factors such as age or body mass index (BMI). The results obtained in this work highlight that in normal pregnant women the skin temperature is symmetrically distributed, with the symmetrical areas differing less than 0.5 degrees C, with a mean value of 0.25 +/- 0.23 degrees C. This study identified a significant negative correlation between the BMI and temperature. Age has been shown to have great influence on the skin temperature, with a significant increase of temperature observed with age. This work explores a novel medical application of infrared thermography and provides a characterization of thermal skin profile in human pregnancy for a large set of ROIs while also evaluating the effects of age and BMI.
2016
Autores
Vaz, P; Pereira, T; Figueiras, E; Correia, C; Humeau Heurtier, A; Cardoso, J;
Publicação
BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Abstract
A multi-wavelengths analysis for pulse waveform extraction using laser speckle is conducted. The proposed system consists of three coherent light sources (532 nm, 635 nm, 850 nm). A bench-test composed of a moving skin-like phantom (silicone membrane) is used to compare the results obtained from different wavelengths. The system is able to identify a skin-like phantom vibration frequency, within physiological values, with a minimum error of 0.5 mHz for the 635 nm and 850 nm wavelengths and a minimum error of 1.3 mHz for the 532 nm light wavelength using a FFT-based algorithm. The phantom velocity profile is estimated with an error ranging from 27% to 9% using a bidimensional correlation coefficient-based algorithm. An in vivo trial is also conducted, using the 532 nm and 635 nm laser sources. The 850 nm light source has not been able to extract the pulse waveform. The heart rate is identified with a minimum error of 0.48 beats per minute for the 532 nm light source and a minimal error of 1.15 beats per minute for the 635 nm light source. Our work reveals that a laser speckle-based system with a 532 nm wavelength is able to give arterial pulse waveform with better results than those given with a 635 nm laser.
2016
Autores
Correia C.M.; Massioni P.;
Publicação
Optics InfoBase Conference Papers
Abstract
Our goal is the provide a tour of recent progress towards rendering Kalman filters suitable for driving astronomical adaptive optics with increasing numbers of degrees of freedom and discuss the prospects to port them to the foreseen real-time architectures.
2016
Autores
Fusco, T; Correia, C;
Publicação
2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO)
Abstract
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.