2016
Autores
Mendes, D; Relvas, F; Ferreira, A; Jorge, J;
Publicação
22ND ACM CONFERENCE ON VIRTUAL REALITY SOFTWARE AND TECHNOLOGY (VRST 2016)
Abstract
Object manipulation is a key feature in almost every virtual environment. However, it is difficult to accurately place an object in immersive virtual environments using mid-air gestures that mimic interactions in the physical world, although being a direct and natural approach. Previous research studied mouse and touch based interfaces concluding that separation of degrees-of-freedom (DOF) led to improved results. In this paper, we present the first user evaluation to assess the impact of explicit 6 DOF separation in mid-air manipulation tasks. We implemented a technique based on familiar virtual widgets that allow single DOF control, and compared it against a direct approach and PRISM, which dynamically adjusts the ratio between hand and object motions. Our results suggest that full DOF separation benefits precision in spatial manipulations, at the cost of additional time for complex tasks. From our results we draw guidelines for 3D object manipulation in mid-air.
2016
Autores
Lopes, DS; Mendes, D; Sousa, M; Jorge, J;
Publicação
COMPUTERS & GEOSCIENCES
Abstract
Too often illustrating and visualizing 3D geological concepts are performed by sketching in 2D mediums, which may limit drawing performance of initial concepts. Here, the potential of expeditious geological modeling brought by hand gestures is explored. A spatial interaction system was developed to enable rapid modeling, editing, and exploration of 3D layer-cake objects. User interactions are acquired with motion capture and touch screen technologies. Virtual immersion is guaranteed by using stereoscopic technology. The novelty consists of performing expeditious modeling of coarse geological features with only a limited set of hand gestures. Results from usability-studies show that the proposed system is more efficient when compared to a windows-icon-menu-pointer modeling application.
2016
Autores
Relvas, F; Mendes, D; Ferreira, A; Jorge, J;
Publicação
2016 23RD PORTUGUESE MEETING ON COMPUTER GRAPHICS AND INTERACTION (EPCGI)
Abstract
Manipulating objects is an essential aspect in virtual environments. Nonetheless, object positioning in immersive virtual environments relying in direct and natural approaches is still difficult. Previous research concluded that degrees-of-freedom separation in mouse and touch interfaces led to positive results. In this document we present a user evaluation to assess if explicit separation of degrees-of-freedom also benefits mid-air manipulation tasks. We implemented a virtual widget based technique that allows users to control a single DOF, and compared it against a direct approach and the PRISM technique, which adjusts the ratio between the hand and object movement. The results of our assessment suggest that full DOF separation benefits precision in spatial manipulations, at the expense of additional time for complex tasks. From these results we proposed a new technique that combines different aspects from the three techniques compared in our assessment.
2016
Autores
Torres, HR; Oliveira, B; Queiros, S; Morais, P; Fonseca, JC; D'hooge, J; Rodrigues, NF; Vilaca, JL;
Publicação
2016 IEEE INTERNATIONAL CONFERENCE ON SERIOUS GAMES AND APPLICATIONS FOR HEALTH
Abstract
In this manuscript, we propose to adapt the B-Spline Explicit Active Surfaces (BEAS) framework for semi-automatic kidney segmentation in computed tomography (CT) images. To study the best energy functional for kidney CT extraction, three different localized region-based energies were implemented within the BEAS framework, namely localized Chan-Vese, localized Yezzi, and signed localized Yezzi energies. Moreover, a novel gradient-based regularization term is proposed. The method was applied on 18 kidneys from 9 CT datasets, with different image properties. Several energy combinations were contrasted using surface-based comparison against ground truth meshes, assessing their accuracy and robustness against surface initialization. Overall, the hybrid energy functional combining the localized signed Yezzi energy with gradient-based regularization simultaneously showed the highest accuracy and the lowest sensitivity to the initialization. Volumetric analysis demonstrated the feasibility of the method from a clinical point of view, with similar reproducibility to manual observers.
2016
Autores
Leite, M; Carvalho, AF; Costa, P; Pereira, R; Moreira, A; Rodrigues, N; Laureano, S; Correia Pinto, J; Vilaca, JL; Leao, P;
Publicação
SURGICAL INNOVATION
Abstract
Introduction and Objectives. Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naive and expert. Materials and Methods. Each participant performed 3 laparoscopic tasksPeg transfer, Wire chaser, Knotin 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Results. Eleven experts and 15 naive participants were included. Three-dimensional video helps the naive group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). Conclusion. The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naive group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures.
2016
Autores
Morais, P; Queiros, S; Ferreira, A; Rodrigues, NF; Baptista, MJ; D'hooge, J; Vilaca, JL; Barbosa, D;
Publicação
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING
Abstract
Minimally invasive cardiovascular interventions guided by multiple imaging modalities are rapidly gaining clinical acceptance for the treatment of several cardiovascular diseases. These images are typically fused with richly detailed pre-operative scans through registration techniques, enhancing the intra-operative clinical data and easing the image-guided procedures. Nonetheless, rigid models have been used to align the different modalities, not taking into account the anatomical variations of the cardiac muscle throughout the cardiac cycle. In the current study, we present a novel strategy to compensate the beat-to-beat physiological adaptation of the myocardium. Hereto, we intend to prove that a complete myocardial motion field can be quickly recovered from the displacement field at the myocardial boundaries, therefore being an efficient strategy to locally deform the cardiac muscle. We address this hypothesis by comparing three different strategies to recover a dense myocardial motion field from a sparse one, namely, a diffusion-based approach, thin-plate splines, and multiquadric radial basis functions. Two experimental setups were used to validate the proposed strategy. First, an in silico validation was carried out on synthetic motion fields obtained from two realistic simulated ultrasound sequences. Then, 45 mid-ventricular 2D sequences of cine magnetic resonance imaging were processed to further evaluate the different approaches. The results showed that accurate boundary tracking combined with dense myocardial recovery via interpolation/diffusion is a potentially viable solution to speed up dense myocardial motion field estimation and, consequently, to deform/compensate the myocardial wall throughout the cardiac cycle. Copyright (C) 2015 John Wiley & Sons, Ltd.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.