2024
Autores
Cavaco, R; Lopes, T; Jorge, PAS; Silva, NA;
Publicação
UNCONVENTIONAL OPTICAL IMAGING IV
Abstract
Spectral imaging is a technique that captures spectral information from a scene and maps it onto a 2D image, featuring the potential to reveal hidden features and properties of objects that are invisible to the human eye, such as elemental and molecular compositions. Augmented reality (AR), on the other hand, is a technology that enhances the perception of reality by superimposing digital information on the physical world. While these technologies have different purposes, they can be considered one and the same in terms of providing an user-centric extension of reality. Spectral imaging provides the information that can reveal the underlying nature of objects, while AR provides the method of visualization that can display the information in an intuitive and interactive way. In this work, we present a novel Unity toolkit that combines spectral imaging and a HoloLens 2 AR device to create an interactive and immersive experience for the user. The toolkit enables the interactive visualization of various elemental maps of a 3D rock model in AR using a simple and intuitive interface. With this technique, the user can select a sample model and an elemental map from a preloaded asset library and then see the map projected onto the rock model in AR, using simple interactions such as zoom adjustment, rotation, and pan of the models to explore features and properties in detail. The toolkit offers several advantages, including better contextual interpretation of the spectral data by placing it in relation to the shape and texture of the rock, increased user engagement and curiosity through the creation of a realistic and immersive experience, and ease of decision-making through the provision of comparative tools. In short, by combining spectral imaging and AR, we present an innovative approach that can enrich the user experience and expand the user knowledge of the environment.
2024
Autores
Teixeira, J; Ribeiro, J; Silva, N; Jorge, P;
Publicação
2024 IEEE SENSORS APPLICATIONS SYMPOSIUM, SAS 2024
Abstract
This paper describes the development of an optical tweezers system that operates in fully automatic mode. It features image recognition for particle tracking, allowing for the optical trapping and analysis of identified targets. The system can perform analysis of forward scattered light and Raman spectroscopy of the trapped particles, facilitating the automated analysis of a large number of samples without manual intervention. By leveraging combined analytical methods and AI for robust classification, this system contributes to the advancement of automated diagnostic tools. Preliminary results demonstrate the system's effectiveness using different kinds of standard and biofunctionalized PMMA microparticles.
2024
Autores
Ribeiro, JA; Jorge, PAS;
Publicação
SENSORS AND ACTUATORS REPORTS
Abstract
Electrochemical impedance spectroscopy (EIS) is a reliable technique for gathering information about electrochemical process occurring at the electrode surface and investigating properties of materials. Furthermore, EIS technique can be a very versatile and valuable tool in analytical assays for detection and quantification of several chemically and biologically relevant (bio)molecules. The first part of this Review (Introduction) provides brief insights into (i) theoretical aspects of EIS, (ii) the instrumentation required to perform the EIS studies and (iii) the most relevant representations of impedance experimental data (such as Nyquist and Bode plots). In the end of this section, (iv) theoretical aspects regarding the fitting of the Randles circuit to experimental data are addressed, not only to obtain information about electrochemical processes but also to illustrate its utility for analytical purposes. The second part of the Review (Impedimetric Detection of Disease Biomarkers) focuses on the applications of EIS in the biomedical field, particularly as analytical technique in electrochemical sensors and biosensors for screening disease biomarkers. In the last section (Conclusions and Perspectives), we discuss main achievements of EIS technique in analytical assays and provide some perspectives, challenges and future applications in the biomedical field.
2024
Autores
Soares, L; Perez-Herrera, RA; Novais, S; Ferreira, A; Silva, S; Frazao, O;
Publicação
PHOTONICS
Abstract
In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of (-3.00 +/- 0.24) pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration.
2024
Autores
Cunha, C; Monteiro, C; Vaz, A; Silva, S; Frazao, O; Novais, S;
Publicação
SENSORS
Abstract
This paper presents an approach to enhancing sensitivity in optical sensors by integrating self-image theory and graphene oxide coating. The sensor is specifically engineered to quantitatively assess glucose concentrations in aqueous solutions that simulate the spectrum of glucose levels typically encountered in human saliva. Prior to sensor fabrication, the theoretical self-image points were rigorously validated using Multiphysics COMSOL 6.0 software. Subsequently, the sensor was fabricated to a length corresponding to the second self-image point (29.12 mm) and coated with an 80 mu m/mL graphene oxide film using the Layer-by-Layer technique. The sensor characterization in refractive index demonstrated a wavelength sensitivity of 200 +/- 6 nm/RIU. Comparative evaluations of uncoated and graphene oxide-coated sensors applied to measure glucose in solutions ranging from 25 to 200 mg/dL showed an eightfold sensitivity improvement with one bilayer of Polyethyleneimine/graphene. The final graphene oxide-based sensor exhibited a sensitivity of 10.403 +/- 0.004 pm/(mg/dL) and demonstrated stability with a low standard deviation of 0.46 pm/min and a maximum theoretical resolution of 1.90 mg/dL.
2024
Autores
Monteiro, CS; Perez-Herrera, RA; Silva, NA; Silva, SO; Frazao, O;
Publicação
FIBER LASERS AND GLASS PHOTONICS: MATERIALS THROUGH APPLICATIONS IV
Abstract
The generation of short pulses in fiber lasers using saturable absorbers made of graphene oxide (GO), focusing on film thickness, was studied and optimized. The saturable absorber comprised a GO thin film deposited onto a single-mode fiber using the spray coating technique. Water-dispersed GO with a concentration of 4 mg/mL, characterized by a high proportion of monolayer flakes, was employed. This thin film was integrated into a cavity ring laser featuring an erbium-doped fiber amplifier (EDFA), resulting in a fiber laser emitting at a central emission wavelength of approximately 1564 nm and having a total cavity length of approximately 120 m. By controlling intracavity polarization, short-pulsed light was generated through mode-locking, Q switching, or a combination of both regimes. This work presents a comprehensive characterization of the cavity ring laser operating under the mode-locking regime. It encompasses an analysis of the spectral behavior, focusing on the evolution of the Kelly's sidebands with increasing pump power, as well as an assessment of its temporal stability. Moreover, the effects of the aging of the saturable absorber material were studied after a time period of 6 months after the fabrication. It was observed that the general characteristics of spectral signal of the laser were maintained, with long-term stability .
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.